43
5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Cleaning of the collecting electrode
When contaminant is built up 2mm or thicker on the collecting electrode, or in the case that even after the
inspection and cleaning, abnormal sparks take place frequently and the mist collector stops by power
shutdown, clean the electrode. Or, irrespective of the accumulation, clean the electrode once in three
months in the manner as follows: To open or close the inspection door, take out the collecting electrode,
follow the procedures which have been explained up to the previous section.
●
1
Pulling out the collecting electrode
Openthe inspection door and pull out the collecting electrode.
●
2
Putting the collecting electrode in the cleaning liquid
Pull out the collecting electrode and put the cleaner for oil removal in
the container and soak the collecting electrode for ten minutes.
●
3
Cleaning the collecting electrode with cleaning liquid
Rinse the eliminator with cleaning liquid and remove the attached
contaminants. The use of an ultrasonic cleaner also provides efficient
cleaning. As needed, take air blowing to wire electrode. Sometimes
adhered resin marks may be left behind on the cleaned electrode
surfaces. These, however, need not be force-removed.
●
4
Giving the collecting electrode a rinse with water or hot water
Rinse the collecting electrode with water of hot water.
●
5
Drying the collecting electrode
Dry completely the water drop attached with the flame or insulator of the
collecting electrode by taking air blow or wiping.
If the contaminants are difficult to take off after immersing for 10
minutes, take the following procedure.
・
After immersing it for about two hours, do air blow to take off the
contaminants.
・
After immersing it all night, rinse it to take off the contaminants.
Caution
If the collecting electrode is installed on the insufficient
condition with water drop, it could cause abnormal spark
discharge Be sure to dry it completely until the eliminator has
no dew after rinsing it.
Caution
Dry completely the water drop
attached the collecting electrode.
Do not use any brushes for removing contaminants. Failure to
do so could damage the wire electrodes.
Caution