42
5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Cleaning of the charging electrode
(continue)
●
3
Cleaning the charging electrode with cleaning liquid
Rinse the eliminator with cleaning liquid and remove the attached
contaminants. The use of an ultrasonic cleaner also provides efficient
cleaning. As needed, take air blowing to needle electrode. The
contamination of the charging electrode will be most serious near the
needles. Sometimes adhered resin marks may be left behind on the
cleaned electrode surfaces. These, however, need not be
force-removed.
●
4
Giving the charging electrode a rinse with water or hot water
Rinse the eliminator in cold or hot water and let it dry completely.
●
5
Drying the charging electrode
Dry completely the water drop attached with the flame or insulator of
the charging electrode by taking air blow or wiping.
●
6
Checking the condition of the charging filter
Dirt and contaminant on the charging filter should be checked, and if any,
wiped away with dry waste or cloth. If the dirt is sticky and will not be
removed easily, use the waste or cloth impregnated with the wash oil (of
the type identical with the collected oil mist). The feed point on the main
unit is also provided with such insulator, which should be cleaned
likewise.
●
7
Checking the condition of the charging
electrode
Before installing the cleaned charging electrode back to the main unit,
check and ensure it is free from foreign substance on, deformation of,
or bends in the plates. The foreign substance on the plate would cause
abnormal spark discharge.
●
8
Installing the charging electrode
Install the charging electrode and close the inspection door.
Do not use any brushes for removing contaminants. Failure to
do so could damage the wire electrodes.
Caution
Do not use the brush to take
off the contaminants.
Feed insulators side of main
body (power supply spring)
Feed
plate
Wipe the contaminants attached
with charging filter or power supply
spring, wipe the contaminants
.
Dry completely the water drop
attached the charging electrode.
If the charging electrode is installed on the insufficient
condition with water drop, it could cause abnormal spark
discharge Be sure to dry it completely until the eliminator has
no dew after rinsing it.