5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Cleaning of the eliminator
Follow procedures given in preceding sections for opening/closing the inspection door for taking out the
eliminator.
●
1
Pulling out the eliminator
Pull out the eliminator.
●
2
Putting the eliminator in the cleaning liquid
Put the duly diluted water-based degreasing detergent in a container, and
immerse it in the detergent for about ten minutes.
●
3
Wash out the contaminants on the eliminator
Using a soft brush, like a test tube brush, etc., scrub away contaminants.
●
4
Rinse the eliminator with water or hot water
Rinse the eliminator in cold or hot water and let it dry completely.
●
5
Drying the eliminator
Dry the eliminator after cleaning completely by air blow or wiping.
(with no water drop)
●
6
Installing the eliminator
Install the eliminator and close the inspection door.
If the contaminants are difficult to take off after immersing for 10
minutes, take the following procedure.
・
After immersing it for about two hours, do air blow to take off the
contaminants.
・
After immersing it all night, rinse it to take off the contaminants.
Caution
If the eliminator is installed on the insufficient condition with
water drop, it could cause spark discharge Be sure to dry it
completely until the eliminator has no dew after rinsing it.
Caution
Dry the water drop attached with
the eliminator completely.