30
5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Error message display
(continue)
Display
Caution
lamp
Inspec
tion
lamp
Alarm
contact
output
Contents
Cause and coping strategy
Error
classifi
cation
door
―
Lighting OFF
Inspection
door open
・
The inspection door is opened.
→
Close the inspection door.
Stop
Er03
―
Lighting Settable
Unusual
temperature
rise
・
The periphery of the electrical equipment has
substantially heated up.
→
Stop the operation and check whether the use
environment temperature and intake air temperature is
in the range from 0 to 40
℃
.
Stop
Er09
―
Lighting Settable
Fan
overload
・
Fan motor overload
→
Remove the cause of the overload.( Ask your nearest
AMANO office or dealer for their services, or charge
your qualified electrician with this task.)
→
After removing the cause, reset the thermal relay.
Stop
Er10
―
Lighting Settable
Short of
charging
electrode
・
Charging electrode is dirty.
→
Clean the charging electrode.
・
The charging electrode was short-circuited.
→
Clean or replace the charging electrode.
→
Remove foreign substances from the wire electrode.
→
Inspect the wire electrode for any deformation;
replace if needed.
・
The charging electrode is not installed.
→
Install the charging electrode.
Stop
Er11
―
Lighting Settable Over voltage
・
The voltage of charging electrode has risen sharply.
→
Remove the cause of the high voltage.(Ask your
nearest AMANO office or dealer for their services, or
charge your qualified electrician with this task.)
→
Check the charging electrode for any poor contact
between its feed spring and feed plate.( If any, replace
the charging electrode with new one)
→
Clean the charging electrode.
・
The charging electrode is not installed.
→
Install the charging electrode.
Stop
Er12
―
Lighting Settable
Short of
collecting
electrode
・
The collecting electrode was short-circuited.
→
Clean or replace the collecting electrode.
Stop
Er20
―
Lighting Settable
Reverse
phase
・
The power connection was made with reversed phase.
→
Reconnect by replacing the orders each other
between R and T phases.
・
Fuse blown or contact failure of fuses.
→
Check the contact condition of fuse of the 5A on F2,
F4 or fuse of the 0.5
A
on F3. Replace it if needed.
Stop
Содержание EM-e II
Страница 51: ...50 9 External dimensions EM 15eⅡ unit mm ...
Страница 52: ...51 9 External dimensions continue EM 30eⅡ unit mm ...
Страница 53: ...52 10 Wiring diagrams ...
Страница 55: ......
Страница 56: ...NFG 930203 27 Printed in Japan T9712A Yokohama Japan http www amano co jp English ...