39
5. Maintenance
(continue)
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Important matters of cleaning the collecting unit
Important
●
Do not use the inflammable substances when cleaning the collecting unit and the machine. If the
inflammable substances are attached to the machine, it could catch fire, cause fire and explosion.
【
Banned inflammable substances
】
Inflammable liquid such as gasoline, kerosene, thinner, toluene etc.
Inflammable cleaner (cleaners such as marked as parts cleaner, break cleaner etc)
●
Use a water-based degreasing detergent to remove oil from the collecting unit and to clean this mist
collector. When using the detergent, observe the instruction written on the container.
●
The metallic side plates are very slippery due to oil on the surfaces. So, please be very careful not to cut
your fingers etc. on the edges at bends in them.
●
An inadvertent touch on the sharp electrical discharging needles could cause injury. Be careful not to
touch the needles when removing or reinstalling the electrical charge poles.
●
To work with the collecting unit, use appropriate protective wear( such as rubber gloves, protective
glasses), and devices.
●
Before opening the inspection door or electrical equipment cover, turn off the power supply to the mist
collector.
●
To do specified performance, install all the collecting units properly.
●
Be sure to dry the collecting unit after cleaning and install the dried unit (with no water drop).
●
If it is a corrosive detergent (of strong acid or strong alkaline), it can not be used for the cleaning.
●
The waste washings must be disposed of according to the rules in your company or regulations by
concerned laws.
●
Use the detergent that will not cause rust, deformation, or corrosion on the collecting unit.
Recommended water-based degreasing detergent: Amano "Degreaser”
Part No; VF-434300
●
Dilute it to the specified concentration, and immerse the contaminated collecting unit in the diluted
detergent for about ten minutes.
●
For the most efficient cleaning, the cleaning solvent should be 50 to 60
℃
.
●
The use of an ultrasonic cleaner also provides efficient cleaning.
●
Important matter when using cleaning goods.
【
Banned cleaning goods and acts
】
High-pressure water sprayer (including equipment spraying high-pressure water by water hose)
Hard brush such as iron brush
Big brush that could apply force to deform electrode
Using cloth for cleaning needle electrodes
Cleaning liquid or water exceeds 60
℃
Do not injure yourself with the points of the electrical discharging needles.
Magnified view at the point of needle
Discharging needle
Charging electrode with needles
Содержание EM-e II
Страница 51: ...50 9 External dimensions EM 15eⅡ unit mm ...
Страница 52: ...51 9 External dimensions continue EM 30eⅡ unit mm ...
Страница 53: ...52 10 Wiring diagrams ...
Страница 55: ......
Страница 56: ...NFG 930203 27 Printed in Japan T9712A Yokohama Japan http www amano co jp English ...