5. Maintenance
Be sure to read and understand on the page 3 to 7 “For safety operation” carefully before use
Display of message window
Message window displays the time of maintenance timer and the contents of error.
By pressing
△
or
▽
switch, the contents of
①
to
⑦
is changed. If
△
or
▽
switch is not pressed, the
displayed contents of
②
to
⑤
is automatically changed per 10 seconds. Error is kept displaying during
error.
Display
Contents
Remarks
TOP
When the
electrical equipment
cover is opened, “door” is
displayed.
During display, the INSPECTION
lamp is lit at the same time.
T
(Hour)
The rest time until set time of
maintenance is displayed.
The rest time is updated per1
hour. By pressing the SET
switch, the total amount of
operation time is displayed.
If you set the timer to “0”,only
four hyphen are displayed.
Error
When the error occurs, the
content is displayed. Until the
error is resolved, the display is
kept displaying.
If there are some errors, the
display is changed per 10
seconds.
HV
(kV)
The voltage of the charging
electrode is displayed in real time.
The voltage is updated continually
per 0.5 seconds.
The voltage is displayed to the
nearest whole number.
LV
(kV)
The voltage of the collecting
electrode is displayed in real time.
The voltage is updated continually
per 0.5 seconds.
The voltage is displayed to the
first decimal place.
Type
The product model is displayed.
Mode
The setting content of data is
displayed.
For setting the mode, change
the display by
△
or
▽
switch.