3 . Changing the Equipment Settings
77
ML-3030AS/3015AS
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
The items that can be protected are as follows.
Display Screen
Item
SCHEDULE Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX/CW waveform switching)
PFB (Power feedback ON/OFF)
PEAK POWER (Laser output peak value)
RESOL (Input resolution of output time)
SLOPE (Time for up-sloping to FLASH1)
FLASH1 (Output time and output value of the first laser)
COOL1 (Non-laser output time to be inserted between FLASH1 and
FLASH2)
FLASH2 (Output time and output value of the second laser)
COOL2 (Non-laser output time to be inserted between FLASH2 and
FLASH3)
FLASH3 (Output time and output value of the third laser)
SLOPE (Time for down-sloping to the last FLASH)
POINT 01 to 20 (Output time and output value of each point for FLEX)
REPEAT (Number of laser light outputs per second)
SHOT (Total number of laser light outputs)
Fn (Schedule editorial assistant function)
MODULATION screen:
DUTY (Duty ratio)
MODULATION (Modulation degree)
FREQUENCY (Frequency)
MODU (Modulation function ON/OFF)
WAVE (Modulation waveform type)
SEAM screen:
SHOT (Laser light output count of each No. of POINT 01 to POINT 20)
POWER (Laser output value % of each No. of POINT 01 to POINT 20)
SEAM (Fade function ON/OFF)
MONITOR Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX/CW waveform switching)
PFB (Power feedback ON/OFF)
HIGH (Upper limit value of laser energy to be monitored)
LOW (Lower limit value of laser energy to be monitored)
STATUS Screen
SCHEDULE (Schedule number)
FORM (FIX/FLEX/CW waveform switching)
PFB (Power feedback ON/OFF)
SHOT COUNT (Resetting the total number of laser light outputs, SHOT COUNT)
GOOD COUNT (Resetting the appropriate number of laser light outputs, GOOD
COUNT)
CONFIG Screen
LASER CONTROL (Laser control setting)
RS-485 COMM (RS-485 communication setting)
TCP/IP COMM (TCP/IP communication setting)
DATE and TIME (Date and time setting)
LANGUAGE
(Language switching)
English (Language switching)
The above setting items become unchangeable and the set values are protected.
⇒
To change any set value, enter the password to display the password setting
screen and set "SCHEDULE EDIT" to UNLOCK.
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......