122
ML-3030AS/3015AS
3 . Connector Functions
Pin No .
Description
2
LASER START
When Pin 3 is closed, the laser beam is output. Make sure that the circuit is left closed
for at least the laser start acceptance time set on the CONFIG screen. When the sig-
nal is input repeatedly, make sure that the circuit is left open for at least the laser start
acceptance time set on the CONFIG screen between each input. Confirm that Pin 13
(Ready output) is closed before inputting the laser start signal.
3
LASER STOP
When outputting the laser using Pin 2, close this pin.
For the repeated output for which the number of outputs is set in "REPEAT" on the
SCHEDULE screen, the laser output is stopped by closing the pin during a laser output.
The closed circuit time should be 1 ms or more.
4
LD-ON/OFF
When this pin is closed, the LD is turned ON.
When this pin is opened, the LD is turned OFF.
5
Guide beam
While this pin is closed, the guide beam is output.
6
TROUBLE RESET
If trouble arises, an alarm is activated. When the cause of trouble has been eliminated
and this pin is closed, the alarm will be canceled. It could take up to 10 seconds to can-
cel the alarm.
7
Unused
Do not connect anything.
8
Unused
Do not connect anything.
9
Old emergency stop (LASER STOP)
When this pin is opened, the equipment is brought to an emergency stop, which is in the
same state as the CONTROL keyswitch is OFF.
<Note>
This pin can be used only when replacing our old products. Use the E-STOP
connector for the emergency stop signal in accordance with machine safety
standards.
10
Input COM
19
0 V OUT
Power supply for external input signals. This pin is exclusively used for the ML-
3030AS/3015AS. Do not use it for any other purpose.
24
Unused
Do not connect anything.
25
CONTROL CHANGEOVER
While this pin is closed, the external input signals are effective.
Output Pins of EXT . I/O (1) Connector
Pin No .
Description
11
LD ON
While the LD is turned on, this pin is closed internally.
12
Guide beam ON
While the guide beam is turned on, this pin is closed internally.
13
Ready
When the laser can be output and a valid schedule is selected, this pin is closed inter-
nally.
<Note>
In the REPEAT mode, the signal is turned off for certain time after laser output
to keep the average power below the maximum rated output.
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......