3 . Connector Functions
131
ML-3030AS/3015AS
Chapter 4 Laser W
elding by External Input/ Output Signals (EXTERNAL
CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
In this wiring example a Pilz PNOZ family safety relay module controls the Laser and
interfaces two external emergency stop buttons. In this example the Pilz device would
also control additional emergency stop functions outside of the Laser using expan-
sion contacts. The more devices which must be implemented the more expansion
contacts must be added to the Safety Relay Module. Any suitable IEC13849-1 com-
pliant safety relay controller is acceptable as long as it is implemented in this manner.
The end user is responsible for verifying compliance of the machine as a whole.
User ESTOP Wiring
ESTOP
P
ow
er
A1
A2
Pilz PNOZ s3
Safety Relay
Module
750103
Input
Input
Reset/
Start
S11
S12
S21
S22
S34
Y32
13
23
14
24
K1
K2
Master machine requires
additional outputs if
more slaves are required
ESTOP
Additional ESTOP (s)
E
ST
O
P
ESTOP CH2 rtn
ESTOP CH 2
ESTOP CH 1
ESTOP Out 1a
ESTOP Out 1b
ESTOP Out 2a
ESTOP Out 2b
Inside the laser
19
14
18
1
16
6
3
5
8
9
21
22
ESTOP CH1 rtn
12
25
11
Interlock rtn 2
Interlock out 2
Interlock rtn 1
Interlock out 1
User Interlock Wiring
(dry contact closure)
24
(Open and close two
contacts simultaneously.)
E-STOP Connector
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......