3 . Connector Functions
125
ML-3030AS/3015AS
Chapter 4 Laser W
elding by External Input/ Output Signals (EXTERNAL
CONTROL)
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
Pin No .
Description
22
Timesharing unit 1
Used for maintenance only.
23
Unused
Do not connect anything.
24
Unused
Do not connect anything.
25
Unused
Do not connect anything.
26
Unused
Do not connect anything.
27
SCHEDULE 1
Select a registered SCHEDULE number by combining schedule
signal inputs 1, 2, 4, 8, 16, 32, 64 and 128.
28
SCHEDULE 2
29
SCHEDULE 4
30
SCHEDULE 8
31
SCHEDULE 16
32
SCHEDULE 32
33
SCHEDULE 64
34
SCHEDULE 128
35
Input COM
Common terminal for input signals.
36
Unused
Do not connect anything.
37
0V
Ground for +24 V DC output.
Output Pins of EXT . I/O (2) Connector
Pin No .
Description
1
24V OUT
Power supply for external I/O.
2
Unused
Do not connect anything.
3
Safety shutter 1 OPEN
While safety shutter 1 is open, this pin closes internally.
<Note>
For ML-30□□AS-110, it has no safety shutter and no beamsplitter. When the
CONTROL keyswitch is turned ON after starting the Laser, this pin closes
internally.
4
Safety shutter 2 OPEN
While safety shutter 2 is open, this pin closes internally.
<Note>
For ML-30□□AS-110, it has no safety shutter and no beamsplitter. When the
CONTROL keyswitch is turned ON after starting the Laser, this pin closes
internally.
5
Unused
Do not connect anything.
6
Unused
Do not connect anything.
7
Unused
Do not connect anything.
8
Unused
Do not connect anything.
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......