REM . I/L Connector
The REM . I/L connector closes the safety shutter and connects the interlock to
cut off laser light in an emergency.
CAUTION
This connector can be used only when replacing our old products . Use the E-STOP
connector for the emergency stop signal in accordance with machine safety
standards .
⇒
Use the following connector mounted on the main unit.
Plug
Case
Manufacturer
116-12A10-2AF10.5
TAJIMI ELECTRONICS CO., LTD.
Pin No .
Description
1
When the section between pin No.1 and pin No.2 is put an open circuit, the safety
shutter is closed.
2
⇒
When the section between 2 pins of this connector is opened by operating the
external interlock, the safety shutter is closed and both guide light and laser out-
put are stopped. Connect this connector to the main interlock, chamber interlock,
door interlock, or other interlock. A multiple number of these interlocks may be
connected in series as required. At delivery, the connector for short circuit is in-
stalled.
⇒
To release the interlock, put the section between pin No.1 and pin No.2 a closed
circuit and press the TROUBLE RESET button displayed on the control panel.
Inside of the laser
REM. I/L connector
+24V
External interlock
0V
RY
1
2
100 mA max.
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......