5 . Monitoring Output
103
ML-3030AS/3015AS
Chapter 2 V
arious Settings
Introduction Part
Inst
allat
ion and
Preparation Part
Operating Part
Maintenance Part
Appendixes
5 . Monitoring Output
MONITOR Screen
On the MONITOR screen, the measured value of monitored laser light is checked
and the monitor value range is set.
FIX / FLEX
CW
How to see the displayed items
: Settable item
ENERGY
(
FIX / FLEX)
Displays the
measured value (J) of laser energy. Each time laser light is
output, the laser energy is measured and its value is displayed. In the
case of a high-speed repeated output, however, the energy is displayed at
certain intervals because the display timing is too quick.
AVERAGE
Displays the average power (W) of output laser light. In the FIX/FLEX
mode, an upper/lower limit judgment is not performed.
HIGH
LOW
Sets the upper limit value "HIGH" and lower limit value "LOW" of the laser
energy (*) to be monitored.
When the laser energy (*) comes out of the set value range, error No.035/
LASER POWER OUT OF RANGE occurs and a monitor trouble is output.
Press the TROUBLE RESET button to clear the trouble.
*: Set the ratio of the set output (PEAK POWER × POWER [%]) in the
CW mode. The trouble is not detected in 0.5 s or less. Also, use the
value as reference.
SHOT COUNT
Displays the total number of laser light outputs.
To reset the display to 0, perform a reset operation on the STATUS screen.
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......