Timing Chart
187
ML-3030AS/3015AS
2-timesharing . . . Operation by external input signals (EXTERNAL CONTROL)
The following diagram shows the lapse of time in the case where a schedule signal
input, BEAM1 and 2 are selected and laser light is output from input unit 1 and 2 re-
spectively with a time difference.
*1
2ms or more
Control changeover time
*2
5s (1h) max.
LD on time
*3
Schedule signal acceptance time (time from a schedule signal input till establishment of schedules)
*4
1s max.
LD output preparation time
*5
2ms or more
Shutter operation changeover time
*6
150ms or more Shutter operation time
*7
Laser start signal acceptance time (time from a signal input till an output)
*8
Time required for the end signal to be output after a laser output
*9
Time required for outputting a signal to indicate whether the laser energy is within the set
upper limit value (HIGH) and lower limit value (LOW) of monitor output
In *3 and *7, the acceptance time is 16 ms but can be changed to 0.1, 1, 2, 4 or 8 ms on the CONFIG screen.
In *8 and *9, the output time is 16 ms but can be changed to 30 or 40 ms on the CONFIG screen.
ON
OFF
ON
OFF
ON
OFF
Introduction Part
Operating Part
Maintenance Part
Appendixes
Installation
and
Preparation
Part
The time set on the CONFIG
screen or more *3
150ms or more *6
*9
Laser beam is projected from Laser Beam Input Unit 1 (Schedule 3)
Laser beam is projected from Laser Beam
Input Unit 2 (Schedule 12)
The time set on the CONFIG screen or more *7
(*: Operation on the user side)
Control Changeover
Input *
External Input
Receivable Output
LD-ON/OFF Input *
LD ON Output
Schedule 1 Input *
Schedule 2 Input *
Schedule 4 Input *
Schedule 8 Input *
Schedule 16 Input *
Schedule 32 Input *
Schedule 64 Input *
Schedule 128 Input *
Ready Output
Beam Select 1 Input *
(except ML-30□□AS-110)
Beam Select 2 Input *
(except ML-30□□AS-110)
Laser Start Input *
(Laser light)
End Output
Monitor Normal/
Trouble Output
5s (1h) max . *2
1s max . *4
The time set on the CONFIG screen or more *7
2ms or more *1
2ms or more *5
The time set on the
CONFIG screen *8
The time set on the
CONFIG screen or
more *3
Содержание ML-3015AS
Страница 1: ...AA04OM1178497 20 OPERATION MANUAL PULSED FIBER LASER WELDER ML 3030AS 3015AS Original instructions...
Страница 21: ...Introduction Part...
Страница 22: ......
Страница 30: ......
Страница 36: ......
Страница 37: ...Installation and Preparation Part...
Страница 38: ......
Страница 52: ......
Страница 53: ...Operating Part...
Страница 54: ......
Страница 163: ...Maintenance Part...
Страница 164: ......
Страница 175: ...Appendixes...
Страница 176: ......