APPENDIX D: COMMUNICATIONS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
D-5
CD-A Originated Command Set
These are commands returned by the CD-A to the host computer via the RS-232 port.
NAME
COMMAND
DATA
SIZE
TYPE
”TY” Read
“CD-A”, Release # and Revision #.
14 Bytes
Example:
“CD-A300A 1.02 C”.
RESET
“RX” Set
Reset an Error, Returns STATUS “TS”
1 Byte
WELD
“TC” Read
The current weld counter
6 Bytes
COUNTER
“TG” Read
Good (6 bytes) and Bad (6 bytes) counters 12 Bytes
LIMITS
“TL” Read
Weld count Limit
6 Bytes
COUNT
“RC” Read
Returns # of stored welds
4 Bytes
REMOTE
”RM” Set
<ACK
OR
NAK>
1 Byte
WELD ZERO “CR” Set
<ACK
OR
NAK>
1 Byte
WELD LIMIT “CS” Set
<ACK
OR
NAK>
1 Byte
LOAD
“
LS” Set
<ACK
OR
NAK>
1 Byte
“
LR” Read
The active schedule #
2 Bytes
REPORT
”RR” Read
Schedule #, {1 to 63}
2 Bytes
Weld Status, {0=Good, 1=Out of Limits}
1 Byte
1st pulse Current,
3 Bytes
2nd pulse Current,
3 Bytes
Weld Number
6 Bytes
15 Bytes Total
REAR
“TR” Read
Returns the rear panel status in HEX
1 Byte
Dual Weld Head (0
th
)
1 Bit
Weld Inhibit (1
st
)
1 Bit
Schedule Lock (2
nd
)
1 Bit
Program Lock (3
rd
)
1 Bit
Emergency Stop (4
th
)
1 Bit
FS2 (5
th
)
1 Bit
FS1 (6
th
)
1 Bit
Fire Switch (7
th
)
1 Bit