CHAPTER 3. USING DISPLAY SCREENS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
3-11
WELD MODE
Press the
MENU
button again to select the
WELD
MODE
field. Use the
or
arrows to select
between the three options;
FS1+FS2+FSW
,
FS1+FS2
and
FSW
.
Each of the options relate to what signals are
required to initiate a weld. The first two
selections incorporate valve control while the
third does not activate the valves. Each option is
defined below:
FS1+FS2+FSW
– Foot Switch 1 and Foot Switch 2 and Firing.
Used with two-level foot switches and air actuated weld heads with force firing switch such as the Amada
Thinline series Weld Heads. Weld Head descends upon activation of FS1, weld begins when FS2 and
FSW inputs are received.
FS1+FS2
– FootSwitch 1 and Foot Switch 2
Used with two level foot switch and non-force pneumatic weld heads. Weld Head descends upon
activation of FS1, weld begins when FS2 input is received.
FSW
– Fire Switch only
Used with Manual Weld Heads or Hand Pieces, weld begins when FSW input is received.