CHAPTER 1: DESCRIPTION
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
1-6
990-430
UP / DOWN Buttons
The UP (
+
) and DOWN (
−
) buttons have two functions.
●
During “normal” operation, up and down buttons are used to scroll through the 63 schedules to select
a desired schedule. The schedule number displays at the lower right corner of the front panel display
screen.
●
In “editing” mode, these buttons also are used to increase or decrease the highlighted values.
Polarity Select
This button is
only
active when the Power Supply is in the “editing” mode. Press this button repeatedly
until the polarity you want displays adjacent to the Pulse 1 or Pulse 2, 3-digit energy display.
For example, the front panel display screen shown on the previous page, indicates positive (
+
) polarity
selected for both Pulse 1 and Pulse 2.
NOTE:
This button is not active on the CD-A1000A
Pulse Select
This button is
only
active when the Power Supply is in the “editing” mode. Press this button repeatedly
until the pulse duration you want is indicated directly below the 3-digit energy display. The front panel
display screen shown on the previous page, indicates
MEDIUM UPSLOPE
pulse duration selected for Pulse
1 and
MEDIUM UPSLOPE
pulse duration selected for Pulse 2.
NOTE:
The
VERY SHORT
setting provides the shortest duration for a given energy setting. The
SHORT
setting will provide the highest peak current for a given energy setting. The
LONG
setting will provide
the lowest peak current and longest duration for a given energy setting.
RUN
Pressing the
RUN
button causes the
BLUE
RUN
screen (shown on the previous page) to be displayed.
Welding is allowed
only
when the
BLUE
RUN
screen is displayed.
MENU
Pressing this button momentarily causes the
Menu
screen to be displayed.
Press and hold this button for 1 second to display the
Menu
editing screen. Welding is
not
allowed when
the
Menu
screens are displayed. Additional instructions for the
Menu
screen are in
Chapter 3, Using
Display Screens.