APPENDIX D: COMMUNICATIONS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
D-3
Host Originated Command Set
These are commands sent by the host computer, via the RS-232 port to the CD-A.
NAME
COMMAND
DATA
SIZE
TYPE
“TY” Read
None. Returns Type of Welder
0 Bytes
STATUS
“TS” Read
None. Returns status of last weld
0 Bytes
REAR
“TR” Read
None. Returns the rear panel status
0 Bytes
RESET
“RX” Set
None. Reset an Error
0 Bytes
WELD
“TC” Read
None. Returns the current weld counter
0 Bytes
COUNTER
“TG” Read
None. Returns Good and Bad Weld counts 0 Bytes
LIMITS
“TL” Read
None. Returns Weld count Limit
0 Bytes
COUNT
“RC” Read
None. Returns # of stored welds
0 Bytes
REPORT
“RR” Read
Request # (1-6 or Retransmission = ‘F’)
1 Byte
READ ORDER, (N=new, O=Old)
1 Byte
(2 Bytes Total)
REMOTE
“RM” Set
0=Local, 1=Remote
1 Byte
WELD ZERO “CR” Set
Reset Weld Counter (zero = 1)
1 Byte
WELD LIMIT “CS” Set
Weld Limit Value
6 Bytes
LOAD
“LR” Read
None, Returns current schedule number
0 Bytes
“LS” Set
01-63 = Sets active schedule
2 Bytes
SCHEDULE “SR” Read Schedule #. Reads current schedule data
2 Bytes
Содержание CD-A Series