CHAPTER 3. USING DISPLAY SCREENS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
3-5
PULSE 1 - ACTION
Press and release the
PULSE 1
button until the
ACTION
parameter is highlighted.
Use the ▲▼
arrows to select the desired action.
If
ACTION
is set to
CONTINUE
, Pulse 2 will be
enabled whether or not Pulse 1 is within limits.
If
ACTION
is set to
INHIBIT PULSE 2
, then Pulse 2
will be enabled
only
when Pulse 1 is within limits.
RESET WELD COUNTER
From the
LIMITS/COUNTERS
edit screen, press
and release the
LIMITS/COUNTERS
button until
the weld counter field is highlighted.
Press the
CLEAR
key to clear the weld counter to
000000
.
NOTE:
The weld counter value can
not
be
changed using the ▲▼ arrows.
EDIT COUNTER LIMIT
From the
LIMITS/COUNTERS
edit screen, press
and release the
LIMITS/COUNTERS
button until
the
COUNTER LIMIT
field is highlighted.
Press the ▲▼ arrows to set a desired limit value
or use the
CLEAR
key to reset to the limit to
000000.
Setting the
counter limit to
000000
will disable the
WELD COUNTER RELAY
output signal available at
the rear panel
37-PIN I/O CONNECTOR
.
NOTE:
At any time before you
SAVE
settings, you may recover original system settings (including the
weld counter values) by pressing the
CLEAR
key at the
SAVE
prompt. To activate the
SAVE
prompt from
the
EDIT
screen, press the
RUN
key and the
SAVE
prompt will now appear. To discard all new settings
and values, and return the system to its previous settings, press the
CLEAR
button.