CHAPTER 3. USING DISPLAY SCREENS
CD-A DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-430
3-7
BAUD RATE
Press the
MENU
button again the highlight the
BAUD RATE
field. This is the speed used for RS-
232 communications.
DEBOUNCE
Press the
MENU
button again for the debounce
setting. Use the
0 MSEC
setting for applications
where a PLC communicates with the unit.
CHAINING START
Press the
MENU
button again to edit the starting
value for a weld chain.
In chaining, all schedules from
CHAINING START
to
CHAINING END
are welded one time and in
numeric order. When the last schedule in the
chain is completed, the system returns to the
CHAINING START
schedule.
Whenever a schedule within a chain is selected,
the chain will start at that schedule. When the last
schedule in the chain is completed, the system
returns to the
CHAINING START
schedule.