Error Messages
The Power Supply displays the following error messages in the bottom line of the display. To clear these
error codes, press either the
RUN
or
CLEAR
buttons. If the error has gone away, the message will then be
removed. If the error is still present, the message will remain on the display.
Error Number
Error Name
Description
Troubleshooting steps
1
Discharge Problem
Contact Factory
The energy setting in the weld
schedule was reduced, or the
schedule number was changed to a
schedule with a lower energy setting.
The unit did not reach this new,
lower energy value within 15
seconds.
1)
Turn off the unit and wait
30 seconds. Turn on the
unit and see if the error
disappears.
2)
If the error persists,
contact
Amada
Weld
Tech for service.
2
Over Current
cycle power to restore
An Over Current condition has
occurred and the unit has locked
out the fire mode.
1)
Cycle the input power to
disengage lock out.
2)
If the error persists,
contact Amada Weld
Tech for service.
3
Firing Switch not closed
within 10 seconds
The firing switch did not close
within 10 seconds of FS2 closing.
Adjust the weldhead and/or
parts to be welded so that the
firing switch closes within 10
seconds of FS2 closing.
4, 5, 6,
7, 8
Internal Communication
Errors
Various internal Errors.
Recycle power. If error
persists, contact Amada Weld
Tech for service.
10
Emergency Stop
The emergency stop input is open.
Close the emergency stop
switch.
11
Chaining End
less than Chaining Start
An error happened in a chaining
sequence.
1)
Reset the chaining
sequence to the first
schedule in the chain.
2)
If the error persists,
contact
Amada
Weld
Tech for service.
14
Over Temperature Error.
Press Run To Restore
The internal temperature of the unit
has exceeded its limit.
1)
Reduce output power or
Reduce the Repetition
Rate.
2)
Discontinue firing and
allow Unit to cool.
3)
If the error persists,
contact Amada Weld
Tech for service.