APPENDIX D: COMMUNICATIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
D-6
990-922
STATUS
”TS” Read
Status
of
unit
or the last weld.
2 Bytes
0
=
GOOD.
1 = Capacitors did not discharge in 15 seconds.
2 = Capacitor does not charge in time.
3 = Firing switch does not close within 10 seconds of FS2 closing.
4
=
The
capacitor
calibration value is outside of limits.
5
=
Internal
EEPROM
memory
error.
6 = Internal EEPROM values corrupted. Default values loaded.
7 = Power board fuse blown.
8 = Communication error between control board and front panel.
9 = Exiting Edit mode.
10 = Emergency Stop (EMO) input is open.
11 = Invalid Chaining start or end value.
12 = Last Weld was out of Limits.
SYSTEM
“YS” Set
<ACK
OR
NAK>
1
Byte
SYSTEM “YR”
Read
BAUD
RATE
(rate)
1 Byte
DEBOUNCE
(0=None,
1=30ms)
1
Byte
BUZZER
(0=Off, 1, 2, 3, 4=loud)
1 Byte
FAST
WELDING
(0=Off,
1=
On) 1
Byte
REMOTE
(0=Off,
1=
On) 1
Byte
CHAINING START, (0=Off, 01-63)
2 Bytes
CHAINING END
(0=Off, 01-63)
2 Bytes
9
Bytes
Total
-------------------------------------------------------------------------
rate
0=9600, 1=19.2 k, 2=38.4 k Baud
Содержание 1000ADP
Страница 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Страница 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Страница 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Страница 14: ......
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 82: ......
Страница 92: ......
Страница 112: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...