CHAPTER 4: OPERATING INSTRUCTIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
4-4
990-922
5.
To modify
pulse duration
, press the
PULSE SELECT
button until the pulse length you want is
indicated beneath the 3-digit energy display.
NOTE:
The
Very Short
setting provides the shortest duration. The
Short
setting
provides the
highest peak current for a given energy setting The
Long
setting provides the longest duration
and lowest peak current for a given energy setting. The
Medium
setting provide and
intermediate option between the
Short
and
Long
settings. Upslope applies to the
Short
,
Medium
and
Long
settings only, and is turned ON or OFF with the
PULSE SELECT
button.
Note:
Pulse duration is not user settable on the 1000ADP
6.
To modify
POLARITY
, in edit mode, press the
POLARITY SELECT
button repeatedly until the
polarity you want is indicated in the display.
Note: Polarity is not user settable on the 1000ADP
7.
To modify the
squeeze time
, press the
SQZ/HOLD
button. The
SQUEEZE
field will be
highlighted. Press the arrow to increase squeeze time or press the arrow to decrease the
squeeze time.
8.
To modify the
hold time
, press the
SQZ/HOLD
button again. The
HOLD
field will be
highlighted. Press the arrow to increase hold time or press the arrow to decrease hold
time.
9.
To modify the settings for Pulse 2, press and hold the
Pulse 2
button to enter edit mode.
10.
Repeat steps 4 through 6 to program the settings for Pulse 2.
11.
Press the
SAVE
button to save any changes made. To exit “editing” mode
without
accepting
changes, press the RUN button on the front panel which will activate the
SAVE
prompt, then
press
CLEAR
to discard changes.
Set Peak Current Monitor Limits
Each of the 63 schedules has an associated set of
Monitor Limits
. To edit these limits, select the desired
schedule, then:
1.
Press the
LIMITS/COUNTERS
button to select this screen.
2.
To edit the limits for Pulse 1, press and hold the
PULSE 1
button for about one second. The
screen will turn black to indicate that the Power Supply is in edit mode. The upper limit for
Pulse 1 will be highlighted. Press the arrow to increase limit or press the arrow to
decrease the limit.
3.
To edit the lower limit for Pulse 1, press the
PULSE 1
button again. The lower limit will be
highlighted. Press the arrow to increase limit or press the arrow to decrease the limit.
4.
To edit the Action for Pulse 1, press the Pulse 1 button again. Press the or arrow to select
between
CONTINUE
or
INHIBIT PULSE 2
.
NOTE:
When
CONTINUE
is selected, Pulse 2 is enabled whether or not Pulse 1 is within
limits. When
INHIBIT PULSE 2
is selected
, Pulse 2 is inhibited when Pulse 1 is out of limits.
5.
Use the
PULSE 2
button to set the upper and lower limits for Pulse 2.
Содержание 1000ADP
Страница 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Страница 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Страница 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Страница 14: ......
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 82: ......
Страница 92: ......
Страница 112: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...