CHAPTER 3. USING DISPLAY SCREENS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
3-10
990-922
RESET DEFAULTS
Press the
MENU
button again to select the
RESET
DEFAULTS
. The default selection is
OFF.
To set all schedules, limits, weld counter, weld
counter limits and all menu items back to their
factory default values, select
ON
, then press
SAVE
to save changes.
To discard changes, press
RUN
to activate the
SAVE PROMPT
and at the prompt, press
CLEAR
to discard changes.
After saving or discarding new settings, the
display will revert to the original screen selected.
FAST WELDING
Press the
MENU
button again to highlight the
FAST WELDING
selection.
When this is set to
OFF
, weld data is saved to
non-volatile memory periodically.
When
FAST WELDING
is set to
ON
, weld data is
saved to non-volatile memory only when the
user presses the
SAVE
button.
See Chapter 4 for more information about the
FAST WELDING
feature.