CHAPTER 3. USING DISPLAY SCREENS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
990-922
3-5
PULSE 1 - ACTION
Press and release the
PULSE 1
button until the
ACTION
parameter is highlighted. Use the
▲▼
arrows to select the desired action.
If
ACTION
is set to
CONTINUE
, Pulse 2 will be
enabled whether or not Pulse 1 is within limits.
If
ACTION
is set to
INHIBIT PULSE 2
, then Pulse 2
will enabled
only
when Pulse 1 is within limits.
RESET WELD COUNTER
From the
LIMITS/COUNTERS
edit screen, press
and release the
LIMITS/COUNTERS
button until
the weld counter field is highlighted.
Press the
CLEAR
key to clear the weld counter to
000000
.
NOTE:
The weld counter value can
not
be
changed using the
▲▼
arrows.
EDIT COUNTER LIMIT
From the
LIMITS/COUNTERS
edit screen, press
and release the
LIMITS/COUNTERS
button until
the
COUNTER LIMIT
field is highlighted.
Press the
▲▼
arrows to set a desired limit
value or use the
CLEAR
key to reset to the limit
to
000000.
Setting the
counter limit to
000000
will disable the
WELD COUNTER RELAY
output signal available
at the rear panel
37-PIN I/O CONNECTOR
.
Содержание 1000ADP
Страница 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Страница 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Страница 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Страница 14: ......
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 82: ......
Страница 92: ......
Страница 112: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...