![Amada 1000ADP Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/amada/1000adp/1000adp_operation-manual_2915799068.webp)
APPENDIX A: TECHNICAL SPECIFICATIONS
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
A-4
990-922
Item
Description
Watt Second
Adjustment Range
125ADP -- 1 to 125 Watt Seconds (Ws) in 0.1 Ws increments for 1.0
10.0 Ws, otherwise
1 Ws increments.
300ADP -- 3 to 300 Watt Seconds (Ws) in one Ws increments
1000ADP – 10 to 999 Watt Seconds (Ws) in one Ws increments
Polarity Selection
Positive, Negative, or Alternating (on 125ADP, 300ADP only)
Squeeze Time
0-2999 msec
Hold Time
0-2999 msec
Weld Counter
0-999999
Action Upon Reaching
Limit
Buzzer sounds after each weld. Output relay activates.
Input Debounce Time
Approximately 32 msec
Control Outputs
(See Appendix B for
details)
Weld ready
(24VAC or 30VDC max, 500mA max)
Weld end
(24VAC or 30VDC max, 500mA max)
Counter reached limit (24VAC or 30VDC max, 500mA max)
24 VDC and return (for optical firing switch)
Environmental
Operating Humidity
Operating Temperature
5% to 95% (Non-condensing)
5°C to 40°C (Ambient Temperature)
Valve power
24 VAC, 0.5A maximum.
24 VDC 0.5 A maximum, including any current drawn from pins 1 and 19 of the 37 pin
I/O connector.
Содержание 1000ADP
Страница 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Страница 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Страница 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Страница 14: ......
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 82: ......
Страница 92: ......
Страница 112: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...