CHAPTER 2: INSTALLATION AND SETUP
125ADP/300ADP/1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY
2-2
990-922
NOTE:
Unlike the
125ADP
and
300ADP
Power Supplies which have internal transformers, the
1000ADP
has a large, external transformer that must be located within 2 meters of the power supply.
Utilities
Power
The Power Supply is shipped with a universally compliant power cable and a North American compliant
115VAC three prong connector. For operation in countries with different AC mains requirements,
remove the male three prong mains connector and replace it with an approved mains power connector
for the country in which the unit is to be used. The required connections for your power cable connector
are described in
Appendix B, Electrical and Data Connections.
Input power requirements for the Power
Supply are as listed below.
Power Input Specifications
Model
Input Voltage,
50-60 Hz,
Single phase (Vrms)
Circuit Breaker
Current (A rms)
Copper Wire
Gauge,
7 strands (AWG)
Wire Diameter
(mm)
125ADP, 300ADP,
1000ADP
100-120 15 10 2.5
125ADP, 300ADP,
1000ADP
200-240 10 10 2.5
Compressed Air and Cooling Water
If compressed air or cooling water service is required for the weld head, please refer to the weld head
manufacturer’s user manual for service specifications.
Содержание 1000ADP
Страница 1: ...990 922 Rev G STORED ENERGY POWER SUPPLY 125 300 1000ADP OPERATION MANUAL...
Страница 8: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY viii 990 922...
Страница 9: ...125ADP 300ADP 1000ADP DUAL PULSE RESISTANCE WELDING POWER SUPPLY 990 922 ix...
Страница 14: ......
Страница 24: ......
Страница 58: ......
Страница 64: ......
Страница 82: ......
Страница 92: ......
Страница 112: ...AMADA MIYACHI AMERICA INC 1820 South Myrtle Ave Monrovia CA 91016 U S A TEL 1 626 303 5676 FAX 1 626 358 8048...