WBSn-2400 and WBSn-2450 System Manual
Appendix A - TroubleshootingUsing the Reset Button of the Base Station
Appendix A - Troubleshooting
Using the Reset Button of the Base Station
113
If the reason you entered Rescue Mode is repeated power interruptions (reason 1 above), click on the
Reboot
button. The unit should restart in normal operation.
If the reason you entered Rescue Mode is because the device does not operate properly and you are not
able to access the EMS utility even after reboot, try solving the problem by to uploading a correct
firmware file without changing the current configuration:
1
Click on the
Choose File
button and navigate to the location of the appropriate dlv file (should be a
firmware file known to be good) and select it. The name to the selected file will be displayed.
2
Select the firmware bank (0 or 1) to which the selected file will be loaded.
3
Click on the
Upload
button. The progress of the upload process is displayed. At the end of the
process the result is indicated.
Figure A-1: Rescue Mode Entry Screen
NOTE!
If you do not login to the system through the simplified web interface within ten minutes of entering
Rescue Mode, the system will automatically reboot and try to load the regular operational version. If you
log in through this interface, the system will stay in rescue mode until rebooted manually.