БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
55
STORAGE, TRANSPORTATION AND DISPOSAL
Table
8
Fault
Possible reason
Recommendations
Drive does not work
(no indication on the
control unit)
No supply voltage or fuse
is blown
Check the supply voltage.
Check, and if necessary, replace the
fuse (fuse parameters should comply
with the original parameters)
The door moves in the wrong
direction
Error in electric
connections.
Check the drive and control units
connections
Door does not stop in final
positions
Final positions are not set
or went wrong, operation
time is set incorrectly
Set up final positions of the
door, increase the operation time
(section ‘6. Settings’, setting ‘
’)
Drive is not controlled
by the remote control
(indicator on the control
does not illuminate)
Remote control code is
not recorded in the control
unit memory
Record the remote control
(section 7. ‘Programming
remote controls’)
Drive is not controlled by
the remote control or the
activation distance of the
remote control is short
(indicator on the remote
control does not illuminate
or is dim)
Low battery in remote
control
Check the remote control battery
and replace, if necessary
Door does not move after
the command Indication
‘
’ on the display
The drive is blocked, or the
drive is in the emergency
circuit mode, or the
electric motor temperature
protection is activated,
or the drive final positions
switches are not connected
properly
Check the correctness of the drive final
positions switches, release the drive,
switch the drive from the emergency
mode using the circuit, let the electric
motor cool down
Door does not move after
the command Indication
‘
’ on the display
The door movement stop
sensor, connected to the
input ‘
S
’ is activated
Remove the reason for
STOP
sensors
activation (e.g., door leaf is open or the
cables are loose)
Drive stops during gate
closing, and the door fully
opens
When the door is
closing the safety device
(photocells, safety margin
sensor) activates due to an
obstacle
Set the activation type based on the
indication on the display (
table
5).
Make sure the closing of the door is
not obstructed
11. STORAGE, TRANSPORTATION AND DISPOSAL
The product shall be stored in its packaging in a closed dry space. Do not expose to atmospheric
precipitation, or direct sunlight. Shelf-life is 3 years from the manufacture date. Transportation
can be performed using all types of covered ground vehicles, with measures to prevent shock
and movement inside the vehicle.
Disposal of the product shall comply with the regulatory and legal requirements on
recycling and disposal, valid in the user’s country. The product does not contain
substances, posing danger to life and health of people, and environment.