БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
49
ADjUSTMENT
TX
RX
NC
NO
COM
- +
- +
X11
PH.T PH1 SE
+24V
+12V S
CL
OP
Figure
4. Photocells connection
TX
RX
NC
NO
COM
-
- +
X11
PH.T PH1 SE
+24V
+12V S
CL
OP
+
TX
RX
NC
NO
COM
-
- +
X11
PH.T PH1 SE
+24V
+12V S
CL
OP
+
TEST
A
B
Figure
5. Photocells connection to perform automatic test of their operation (
Phototest
):
A
—photocells with typical connection,
B
—photocells with special output
TEST
6.
ADjUSTMENT
The operation parameters are set using the display and control unit module buttons. To enter
the operation parameters set-up mode, press and hold the button ‘
F
’ on the control module
for at least 3 seconds (
fig.
2). Select the necessary settings (
table
7) using the ‘
F
’ button. The
selection of the required parameter value is performed by pressing or holding buttons ‘
+
’ or ‘
−
’
on the control unit module. Press button ‘
F
’ to confirm the selected value. Press and hold the
button ‘
F
’ for at least 3 seconds to exit the operation parameters set-up mode, in this case all
the selected values will be saved. All control commands for the door movement are ignored in
the operation parameters set-up mode.
To return to the initial settings of the control unit module (default settings) enter the operation
parameters set-up mode (‘
’on the indication display), press and hold the button ‘
CL
’ for at
least 3 seconds on the control unit module (
fig.
2). Short-term indication ‘
’ on the display
means deletion of all previously set values and return to the default values.