БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
48
ELECTRICAL INTERFACES
Socket
Contacts
Device
designation
Connection description
X11
SE
8,2 kOm/
OSE
Door leaf lower margin safety device input;
the contact of the door with an obstacle during closing (activation
of a sensor) causes it to stop moving and then fully open.
In settings (section ‘6. Adjustment’) the following can be
selected, depending on the connected safety device: resistive
sensor / 8.2 kOhm or optoelectronic sensor /
OSE
(
fig.
3)
PH1
Photo
Safety device input (photocells /
fig.
4) with a
NC
contact.
The activation of the device during closing results in stop,
followed by full opening;
if activated during the pause time countdown in the automatic
mode, the pause is reset and the countdown starts anew, or the
pause is reset and the door is closed automatically after 5 seconds
(section ‘6. Adjustment’)
PH.T
—
Output for automatic operation test (
Phototest
) of devices,
connected to input ‘
PH1
’—the operation of the photocells is
checked before movement by short-term disconnection and then
reconnection of the power to the photocells transmitter.
fig.
5A—connection of typical photocells to perform
Phototest
(‘direct’
Phototest
);
fig.
5B—connection of photocells with special output ‘
TEST
’ of the
transmitter (‘inverse’
Phototest
).
The activation of the output operation is described in section
‘6. Adjustment’
X9
OP.L
Limit switch
OPEN
Input of the drive opening final position switch with
NC
contact
—
Common contact for the final positions switches
CL.L
Limit switch
CLOSE
Input of the drive closing final position switch with a
NC
contact
X6
—
External antenna
RG58
X11
PH.T PH1 SE
+24V
+12V S
CL
OP
GN
WH
BN
TX
RX
Ou
tp
ut
CO
M
+V
TX
and
RX
— optoelectronic
sensor transmitter and receiver
GN
— green wire
BN
— brown wire
WH
— white wire
Figure
3. Connection of the optoelectronic safety sensor
for the door leaf lower margin /
OSE
(Optoelectronic Safety Margin)