БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
52
PROGRAMMING REMOTE CONTROLS
Settings
indication
Settings description
—1 sec
—2 sec
…—…
—60 sec
Lower margin safety sensor
Selecting the type of lower margin safety sensor (
OSE
), connected to input ‘
SE
’:
—optoelectronic sensor
OSE
(
fig.
3)
—resistive sensor 8.2 kOhm (
fig.
2).
Default settings
.
Programming remote controls AT-4N / AT-4A
To enter a remote control into the unit memory select a remote control number without
a dot in the menu (e.g.,
—record number is available), then press the selected button
on the remote control, display indication will blink several times and the remote control
number with a dot will be displayed (
—record number is taken). Maximum number of
recorded remote controls is 60. The distance of the remote-control operation in free open
space is not less than 50 metres.
To determine the remote-control record number (if the remote control is already recorded),
press any button on the remote control in the setting
‘
’ and the display will show
the remote-control record number. To assign (re-record) another remote-control button
show the remote control record number on the display in the setting
‘
’ and press the
selected button on this remote control, and then the number with a dot will blink several
times on the display, which means the assigned remote control button is in the unit
memory.
To delete a specific remote-control select the number, corresponding to this remote
control, in the settings
‘
’ press and hold the button ‘
CL
’ for at least three seconds on
the control module, the display indication will blink several times and number without a
dot will be shown, which means the deletion of the remote control from the unit memory.
To delete all remote controls, press and hold the button ‘
CL
’ for at least three seconds on
the control module, while the display shows the settings
‘
’, the display indication
will blink several times, which will mean the deletion of all remote controls from the unit
memory.
In the automatic mode (settings
‘
’) the control of the door movement by the remote
control, which has given the first command to open, is performed in the sequence
‘Full opening—Close—Stop—Full opening …’. The activation of another recorded remote
control during the pause time countdown to automatic closing of the door causes the
pause time to reset and start a new pause time countdown.
7.
PROGRAMMING REMOTE CONTROLS
The control of the drive using one of the buttons on the remote control is performed using the
mode of step-by-step control according to the selected operation mode (section ‘6. Adjustment’)
if the remote control used is an (
AT-4
or
AT-4N
/
AT-4A
).
Y
Clear up the module memory from all previously recorded remote controls before first
programming of the remote controls.
Before recording a remote control, remove the socket
Х6
(
fig.
2) with antenna. When the re-
mote control has been recorded, replace the socket
X6
. If a remote control is lost, the lost
remote-control number should be deleted from the module memory (only for remote controls