БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
42
PRODUCT DESCRIPTION
Please, make sure that the mains supply is equipped with protective earthing. Make sure that
the earthing system is properly made and connected.
The part of the electric mains, to which the product is connected, should be equipped with
a protection device (three-pole automatic circuit breaker) for 400 V / 50 Hz mains.
The parameters of the electric cables used (section, number of wires, length etc.) should comply
with the connection diagram, device power, laying distance, way of laying, ambient conditions.
Use multicore cable with double insulation.
The electrical cable should be protected from contact with any rough and sharp surfaces by
using corrugated tubes, pipes and cable ducts to lay the cables.
The instruments and materials used should be fully intact and comply with the safety norms,
standards and instructions in force.
The recommendations, presented in the manual, shall be deemed as the example, as the location
of the system installation may differ. The task of the installation engineer is to choose the most
suitable solution. In his work, he should follow the norms and standards in force.
The company does not perform direct control of the installation of the product and automa-
tion devices, their maintenance and operation, and cannot be responsible for the safety of the
product installation, operation and maintenance.
The company reserves the right to introduce changes in this manual and the product construc-
tion without prior notification, but preserving the same functional capabilities and designation.
The content of this manual cannot be used as the basis for legal claims.
2.
PRODUCT DESCRIPTION
The unit is designed to control the drives of industrial sectional doors. The direct use is to control
the operation of these drives ASI100, TR-5024-400 / TR-10024-400 / TR-13018-400.
The control keys and indication LEDs (
table
1) are located on the body of the unit (
fig.
1). The
package supplied with the unit includes: cable 5G1.5 mm
2
(~ 0.6 m long) with a plug of the type
015 3P + N + E 16A / 6h to connect to the mains, two remote controls
AT-4N
, a pattern to mark the
assembly of the control unit (assembly size 165 mm × 239 mm).
1
STOP
2
3
190
28
0
25
4
180
Figure
1. Control unit (sizes are shown in millimetres)