68 • MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual
Troubleshooting
PROformance: No Grease Collection Operation
Is the control set up to
operate a GC system?
Yes
Turn on grease collection
in option set up screen.
Is grease collection
activated in the cooking
program?
Yes
Is the grease collection pump being
energized on its timed cycle?
Determine which leg of
the power is missing and
correct.
Is the grease collection pump
running?
Yes
Remove pump
and clear obstruction between
condensate pan and pump,
or between pump and grease
collection bin.
No
Activate grease collection
in the program and retest.
A1 is L1 being switched
from Control Board (CB)
terminal X02 which is
supplied by Option Board
(OB) terminal X02 pin 1.
A2 is L2 supplied by CB
terminal X02 pin 3 which is
supplied from OB terminal
X02 pin 4.
Replace the faulty grease
collection pump.
Yes
No
No
No
Is the appliance equipped
with a grease collection
(GC) pump?
Yes
Grease collection system is
not available.
No