MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual • 51
Touch the Cleaning icon found on the home screen.
If oven is too hot to proceed, the Oven Too Hot warning
screen will appear. Open the oven door to allow the oven to
cool below 150°F (66°C). When the oven is fi nished cooling,
begin the cleaning procedure again.
Select Rinse, Light, Normal, Heavy-duty, or Heavy-duty
PLUS cleaning level.
• Wear rubber gloves to remove oven interior drain
cover screen.
• Tear open or cut open the plastic wrap surrounding the
cleaning tablets.
• Remove tablets from the packaging. Discard packaging.
Insert the appropriate number of CombiClean®
CombiTabs™ directly into the oven cavity drain or spray
CombiClean liquid cleaner inside the oven.
• The number of tablets to be used can be increased
depending upon how dirty the interior is.
• Close oven door.
Touch the green check mark key to begin the
cleaning cycle.
Oven shuts down when the cleaning cycle is
complete. Leave door slightly ajar when fi nished.
CT PROTouch™ with CombiClean®
Five (5) cleaning levels are offered: rinse (20 minutes), light (30
minutes), normal (1 hour 20 minutes), heavy-duty (2 hours 6
minutes), and heavy-duty PLUS (3 hours 30 minutes) cleaning.
CombiClean® 18 gram CombiTabs™ (CE-36354) or Combitherm®
liquid spray cleaner (CE-24750) may be used. Side racks and
shelves may remain inside oven during cleaning. Remove the
optional Grill Grate from the oven interior and wash separately
in hot, soapy water to preserve the special non-stick coating.
Remove the smoker tray and any solid wastes from the drain
screen and oven interior to prevent blockage.
NOTICE:
If a power outage were to occur during any of the
cleaning cycles, the oven will begin a six (6) minute
forced-rinse cycle.
Be sure the water is turned on.
Rinse
Heavy-duty
Normal
Light
Number
of tablets
to use
Heavy-duty PLUS
Cleaning
time
needed
Drain
opening
Begin
cleaning
cycle
Return to
previous
screen
NOTICE:
If the oven is equipped with the
optional grease collection system,
3 cleaning levels are available.
Wear
rubber
gloves
NOTICE:
All tablets should be placed inside the drain as
best as possible and drain screen replaced before
starting the cleaning cycle. Tablets placed on top of
the drain cover or placed on the bottom of the oven
will not dissolve properly and will cause the oven
interior to deteriorate.
CT PROTouch™ with CombiClean®
Cleaning and Maintenance
Содержание COMBITHERM CT PROFORMANCE 10-10E