34 • MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual
Options
2
1
Grease Filter
(5017362):
Cleaning frequency should be based on oven usage
with a maximum of two weeks between cleaning
if the oven is used for non-grease laden products
or steam applications only. Grease laden products
require cleaning frequency of at least once a week.
Remove the grease fi lter by pulling it straight out
of the housing. Place the fi lter in the dishwasher
or wash separately by placing in hot, soapy water
until all grease and particles have been removed.
Rinse thoroughly. Allow the fi lter to air dry before
reinstalling.
To replace the grease fi lter, the air fl ow arrow on the
fi lter casing should be pointing toward the hood fan.
2
Charcoal Filter
(Class I - FI-36620):
The charcoal fi lter should be inspected once a month
for contaminants. Replacement must be made at
a minimum of three month intervals — more oft en
if heavy contaminants are visible or if the fi lter no
longer controls odors.
To remove the fi lter, pull and slide out while holding
the bottom housing. When replacing the fi lter, make
certain the air fl ow arrow(s) point toward the hood
fan, and that the fi lter is replaced in the three-sided
metal frame provided with the hood.
1
NOTICE:
A pressure switch is used to detect when the airfl ow
through the charcoal fi lter is reduced by 25% -
indicating a possible blockage. This will generate an
E101 error message on the oven control display. The
fi lters will need to cleaned or replaced.
If the fi lters are not seated properly, an error code
E102 will appear on the oven control display at the
end of a cooking cycle.
Quarter Turn Release
(access to filters)
Quarter Turn Release
(access to filters)
CombiHood PLUS™ Ventless Hood Option
Содержание COMBITHERM CT PROFORMANCE 10-10E