42 • MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual
Cleaning and Maintenance — CTP
Weekly Maintenance
On a weekly basis, the heat exchanger on gas
models and convection elements on electric models
must be inspected.
• Remove all wire shelves from inside the
appliance.
• Remove left side rack from the oven cavity.
• Loosen the thumb screw(s) on the fan panel and
swing the fan guard cover plate toward the back
of the oven.
• Inspect the heat exchanger on gas models for
signs of grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to images A and B.
• Inspect that the fl ue pipe seal is tight and intact.
Refer to image C.
• Inspect the convection elements for signs of
cracking, grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to image D.
A
B
D
C