56 • MN-35949 • Rev 04 • 06/16 • Combitherm® CT PROformance™ Series • Technical Service Manual
Error
Code
Error Call Out in Display
Description of Error
Possible Cause(s)
E23
B4 Boiler Probe Fault
Boiler temperature probe
defective or disconnected
— B4 boiler temperature probe defective.
— B4 probe wires connected backwards.
E24
B5 Bypass Probe Fault
Bypass steam temperature probe
defective or disconnected
— B5 bypass steam temperature probe defective.
— B5 bypass steam temperature probe wires connected
backwards.
E25
B3 Condensor Probe Fault
Condensor water temperature
probe defective or disconnected.
— B3 condensor temperature probe defective.
— B3 condensor probe wires connected backwards.
E26
N8 Boiler Safety Temperature
Probe Fault
Boiler heating element
protection probe defective or
disconnected.
— N8 boiler temperature probe defective.
— N8 probe wires connected backwards.
E27
Boiler Element Temperature
High
Boiler protection heat element
temperature detected by N8
probe is more than 266°F (130°C)
for more than 25 seconds, or has
reached 275°F (135°C).
— Calcium build up in boiler.
— Check wiring to all components mentioned below.
— Steam element contactor locked/on.
— N8 boiler temperature probe defective.
— N8 probe wires connected backwards.
— Water level probe has calcium buildup.
E34
Steam Generator Drain Pump
Fault
If water level does not drop
below lower water level probe
aft er three minutes when
steam generator drain pump is
activated in cleaning program.
— Calcium build up in steam generator drain pump.
— Boiler drain pump defective.
— Relay board, high voltage, defective.
— Water level probe defective.
E36
Steam Temperature High
In Steam program, cavity
temperature N6 is measuring in
excess of 395ºF (200ºC) for more
than 60 Seconds.
In Combination program, cavity
temperature N6 is measuring in
excess of 520ºF (270ºC), for more
than 60 Seconds.
In Retherm program, cavity
temperature N6 is measuring in
excess of 395ºF (200ºC), for more
than 60 Seconds.
In Cleaning program, cavity
temperature N6 is measuring in
excess of 395ºF (200ºC), for more
than 60 Seconds.
— Water supply is shut off .
— Low water pressure.
— Water injection pipe, calcium build up.
— Water flow valve defect or calcium build up.
— Double water solenoid valve defective (Y1).
— Relay board, high voltage, defective.
E40
B3 Fault
B3 probe shorted to ground
— Defective or miss wired probe.
E41
B4 Fault
B4 probe shorted to ground
— Defective or miss wired probe.
E42
B5 Fault
B5 probe shorted to ground
— Defective or miss wired probe.
E43
N6 Fault
N6 probe shorted to ground
— Defective or miss wired probe.
E44
N8 Fault
N8 probe shorted to ground
— Defective or miss wired probe.
E45
B10 Fault
B10 probe shorted to ground
— Defective or miss wired probe.
Error Codes
continued
on
next
page
Error Codes