background image

TECHNICAL MANUAL

Operation, Maintenance, Troubleshooting, Wiring Diagrams

CTC6-10E

CTC10-10E

CTC7-20E

CTC10-20E

CTC20-10E

CTC20-20E

M N - 3 5 9 4 9     •     R e v   0 4     •     0 6 / 1 6     •     C o m b i t h e r m ®   S e r i e s     •     T e c h n i c a l   S e r v i c e   a n d   T r a i n i n g   M a n u a l 

CTC6-10G

CTC10-10G

CTC7-20G

CTC10-20G

CTC20-10G

CTC20-20G

CTP6-10E

CTP10-10E

CTP7-20E

CTP10-20E

CTP20-10E

CTP20-20E

CTP6-10G

CTP10-10G

CTP7-20G

CTP10-20G

CTP20-10G

CTP20-20G

CT CLASSIC™

CT PROFORMANCE™

Содержание COMBITHERM CT PROFORMANCE 10-10E

Страница 1: ...M N 3 5 9 4 9 R e v 0 4 0 6 1 6 C o m b i t h e r m S e r i e s T e c h n i c a l S e r v i c e a n d T r a i n i n g M a n u a l CTC6 10G CTC10 10G CTC7 20G CTC10 20G CTC20 10G CTC20 20G CTP6 10E CTP...

Страница 2: ...outside the property and immediately contact your gas supplier If unable to contact your as supplier contact the fire department Please post the following instructions in a prominent location in the...

Страница 3: ...od Trolley Cleaning 50 CT PROTouch with CombiClean 51 Error Codes 54 Error Codes 54 Troubleshooting 62 PROformance Appliance Dead No Display or Operation 63 PROformance Electric Boiler Free No Steam P...

Страница 4: ...iler Free No Steam Production Steam at 212 F 100 C 87 PROformance Gas Boiler Free No Steam Production Steam Below 212 F 100 C 88 Classic Gas Boiler Free No Steam Production Steam Below 212 F 100 C 89...

Страница 5: ...ooking functions As the name implies it is fully operable by touch Graphic controls The highly visual graphic based control with logical procedures ensure that correct steps are followed every time An...

Страница 6: ...e purpose limitations and associated hazards of this appliance Operating instructions and warnings must be read and understood by all operators and users We recommend regular training of your staff to...

Страница 7: ...apply caster brakes on mobile appliances or accessories when these are not being moved These items could move or roll on uneven floors and cause property damage or serious injury Be extremely careful...

Страница 8: ...o not steam clean hose down or flood the interior or exterior with water or liquid solution of any kind Do not use water jet to clean Failure to observe this precaution will void the warranty WARNING...

Страница 9: ...en when the oven is next powered up Return to Home Screen Press the red arrow if the PROtouch screen does not need to be calibrated Begin Calibration Process Press the green check mark if the Touch sc...

Страница 10: ...trail info to USB stick Upload odometer info to USB stick Return to previous screen Upload Download Screen Upload Download Settings Service Mode password protected Utility Screen Return to home scree...

Страница 11: ...th these special circumstances Remove the cap of the USB port on the oven Insert the USB stick If the USB stick is not recognized by the Combitherm a question mark will appear on screen Try again with...

Страница 12: ...next setting screen Return to previous setting screen When a setting has been selected the graphic will be vibrant in color while the alternate choice will appear faded and gray In the illustration ab...

Страница 13: ...ming Return to previous screen Preventative Maintenance Screen Ventless Hood Filter Replacement Utilities Return to home screen Increase or decrease alarm setting to match your preferred timelines Pre...

Страница 14: ...ious screen Return to Home Page Enter Chosen Cooking Mode Chosen Entry Field Allowable Temperature Range Entry Keypad Return to previous screen NOTE When a cooking mode has been selected it will appea...

Страница 15: ...wer Level Multiple Fan Speeds The PROtouch control includes ve different fan speeds The reduced fan speed function is useful for ow sensitive products such as souf s and meringues or any products affe...

Страница 16: ...ating Preheat Cool Down Return to previous screen Cool Down Feature The cool down feature provides the operator with the ability to lower the temperature of the oven compartment at an accelerated pace...

Страница 17: ...he illustration at right 72 is shown Rapid Cool available on boiler free models only This function when used with a program rapidly removes heat from the oven cavity Swiftly move from a high cooking t...

Страница 18: ...ration CTP CT PROformance Factory Default Settings Cooking Mode Oven Temperature Core Temperature Cooking Time Steam 212 F 100 C 160 F 70 C 25 minutes Combination Steam 350 F 175C 160 F 70 C 70 minute...

Страница 19: ...time or set continuous time by touching Touch the green Check Mark icon to confirm change To Cook by Product Core Temperature Touch the area to the right of the probe icon Type in desired temperature...

Страница 20: ...area to the right of the time icon Type in desired time or set continuous time by touching Touch the green Check Mark icon to confirm change To Cook by Product Core Temperature Touch the area to the...

Страница 21: ...heck mark key to confirm change To Cook by Product Core Temperature Touch the area to the right of the Probe icon Type in desired temperature Touch the green check mark key to confirm change Insert pr...

Страница 22: ...h the green Check Mark icon to confirm change Insert probe into product Set available auxiliary functions as desired such as energy level fan speed multi shelf timer steam injection etc Touch the Star...

Страница 23: ...to begin cooking The actual internal product temperature will appear next to the probe icon during operation To change the set value for core temperature touch the temperature next to the probe icon a...

Страница 24: ...d of one hour If you would like assistance you are invited to contact an Alto Shaam corporate chef for recommendations NOTICE Always keep the oven door closed whenever operating the smoking function T...

Страница 25: ...me Touch the area to the right of the time icon Type in desired time Touch the green check mark key to confirm change To Activate CombiSmoke Touch auxiliary function smoking icon Touch the Start icon...

Страница 26: ...nctions For example If the recipe requires a reminder to open the door at the end of the segment touch the Door icon If the recipe requires a rest period touch the Rest icon If the recipe requires rap...

Страница 27: ...efore loading food into the oven Touch the Cookbook icon Locate food item program by scrolling through pages using arrows or Look Up icon Touch preprogrammed food item icon Oven begins operating autom...

Страница 28: ...previous step Insert a step Edit as necessary When there are no further changes to be made touch the Save icon Enter the name of the recipe if it is to be changed Touch the green check mark key to co...

Страница 29: ...enter in a name for the recipe folder Touch the green check mark to confirm the folder name Continue to add recipe folders as necessary Touch the recipe utility icon to add programmed recipes to the f...

Страница 30: ...icon of the recipe to be marked A gold star will appear at the top left of the recipe icon All favorites can be viewed when you touch the gold star while viewing the list of saved recipes To Lock Save...

Страница 31: ...ed indefinitely until the information is downloaded Once downloaded the information is removed from the ovens memory Best practice would be to download the information every 30 days to a USB stick Thi...

Страница 32: ...is not recognized by the Combitherm oven a question mark will appear on screen Try again with another flash drive device or call Alto Shaam Service When the data has made a successful transfer to the...

Страница 33: ...umes and vapors are circulated through the hood condensed steam drains from a drain at the rear of the hood An activated charcoal filter cleans the air before venting it out the top of the hood CombiH...

Страница 34: ...6620 The charcoal filter should be inspected once a month for contaminants Replacement must be made at a minimum of three month intervals more often if heavy contaminants are visible or if the filter...

Страница 35: ...lve handle to the ON position If this auxiliary function has been chosen while setting your cooking mode the automatic grease collection system is electronically activated during the cooking process u...

Страница 36: ...DEATH NEVER operate this appliance in a cleaning mode without the liquid cleaner connected with a kink in the cleaning hose line or with an empty liquid cleaner container Failure to do so may result...

Страница 37: ...more limited basis Oven Cool Down Process Cooking process must be inactive Press Cool Down button until LED lights LED remains ON while in Cool Down mode Press DecreaseValue or IncreaseValue to adjust...

Страница 38: ...just temperature with arrow keys Press the Cook Time key adjust time with arrow keys Press Fan Speed key to set to High or Low Load food into oven Press the Start Stop key 160 F 00 00 Steam 160 F 00 0...

Страница 39: ...sion from being placed on the connector WARNING ELECTRIC SHOCK HAZARD To prevent SERIOUS INJURY or DEATH your appliance must be secured to building structure to prevent unintended movement Any applian...

Страница 40: ...protective clothing eye protection face protection Use only outdoors or in a well ventilated area Avoid release to the environment Store in a locked and well ventilated place Keep container tightly c...

Страница 41: ...THIS ITEM DAILY The acids and related compounds found in fat particularly chicken fat will weaken the composition of the gasket unless cleaned on a daily basis Wipe with a hot soapy cloth TO ADDITION...

Страница 42: ...he oven cavity Loosen the thumb screw s on the fan panel and swing the fan guard cover plate toward the back of the oven Inspect the heat exchanger on gas models for signs of grease and or carbon buil...

Страница 43: ..._ Daily Inspection Checklist Inspect clean Monday Tuesday Wednesday Thursday Friday Saturday Sunday Product probe thermometer Door gasket inner door seal Inner door glass Front drip tray Touchscreen o...

Страница 44: ...carbon buildup Inspect Behind the fan panel inside the oven cavity for signs of scale buildup Inspect The heat exchanger for any signs of major deformation If yes immediately remove from service and...

Страница 45: ..._________ Monthly Inspection Checklist Inspect Test Proper draining of the oven cavity Inspect All drain lines for leaks or clogs EB Descale the steam generator Inspect Oven cavity for any signs of sc...

Страница 46: ...e hose Inspect Low pressure relief valve hose E Inspect Convection element seal from the electrical compartment G Inspect Gas heat exchanger seal from the electrical compartment Inspect N6 oven temper...

Страница 47: ...nge ESG models only G Inspect Oven cavity ceiling flange flange gasket ESG models only G Tighten Burner flange bolts G Tighten Igniter flange bolts Inspect Heat exchanger weep holes to ensure they are...

Страница 48: ...e version update if not current Record Water pressure static dynamic Record Line voltage across all lines Record Line voltage to ground on each line Record Amperage across all three legs when heating...

Страница 49: ...serve this precaution will void the warranty Always use the proper cleaning agent at the manufacturer s recommended strength Contact your local cleaning supplier for product recommendations Cleaning M...

Страница 50: ...CLEANING PROCEDURES 1 Remove all food debris from probe between loads and at the end of each production shift Wipe the entire probe probe cable assembly probe prongs and probe holding bracket with a...

Страница 51: ...nutes normal 1 hour 20 minutes heavy duty 2 hours 6 minutes and heavy duty PLUS 3 hours 30 minutes cleaning CombiClean 18 gram CombiTabs CE 36354 or Combitherm liquid spray cleaner CE 24750 may be use...

Страница 52: ...tic Liquid Cleaning Three 3 cleaning levels are offered rinse 20 minutes normal 2 hours 6 minutes and heavy duty PLUS 3 hours 30 minutes cleaning Liquid cleaning solution CE 36457 or Combitherm liquid...

Страница 53: ...splay RIN Cook time display area will display TO CLEAN THE OVEN Press the Cleaning key Insert appropriate number of CombiClean tabs as directed by the LED Screen CLn4 appears The 4 refers to the numbe...

Страница 54: ...ctive E03 Fan Motor Error Fan motor does not spin after 60 seconds detected by the Hall Sensor Error 03 does not appear if error E53 is detected first Check wiring to all components listed below If LE...

Страница 55: ...robe Calcium build up in boiler Check wiring to all components mentioned below Steam element contactor locked on B4 boiler temperature probe is defective B4 probe wires connected backwards Water level...

Страница 56: ...buildup E34 Steam Generator Drain Pump Fault If water level does not drop below lower water level probe after three minutes when steam generator drain pump is activated in cleaning program Calcium bui...

Страница 57: ...or safety switch did not open Alignment issue between motor cam and vent motor safety switch micro switch Faulty vent valve motor Faulty vent valve safety switch micro switch E56 Vent 2 Not Open Upper...

Страница 58: ...ive E94 Communication Error TO Interface Board No signal transfer for more than 5 seconds between the Interface Board IB and the Control Board CB Check CAN cable connections CAN cable defective Relay...

Страница 59: ...ontactors stuck closed Failed Y1 solenoid Obstruction between Y1 solenoid and injection pipe Improperly connected drain Condensate pan clean out not closed Improperly wired high limit switch at the sw...

Страница 60: ...er Motor Over Current Lower Motor over current detected Possible Lower VFD failure E224 Lower VFD Current Peak Lower VFD current peak detected Possible Lower VFD failure E225 Lower VFD EEPROM Error Lo...

Страница 61: ...than 199 F 93 C Current Peak LED flashing sequence with 4 flashes per period Blocked motor detected by current peak monitoring from 900 rpm rotating field Overcurrent LED flashing sequence with 5 flas...

Страница 62: ...35949 Rev 04 06 16 Combitherm CT PROformance Series Technical Service Manual Troubleshooting ALL TROUBLESHOOTING TREES BASED ON A 7 20 208 240V 3PH MODEL RUNNING ON ECO POWER SETTING UNLESS OTHERWISE...

Страница 63: ...power supply Replace faulty power supply Yes Is there 12 VDC across the Control Board CB terminal X07 pins 1 4 Repair wiring between power supply and the Control Board CB terminal X07 Is there 12 VDC...

Страница 64: ...the element loops at the convection elements Repair the wiring between contactors and elements Are all element loops drawing current Replace the faulty element assembly Yes Is the Y1 solenoid being en...

Страница 65: ...cross terminals 1 3 5 on the K41 K44 contactors Replace faulty contactor s No Yes Is there voltage across element loops at the convection elements Repair the wiring between contactors and elements Yes...

Страница 66: ...een contactors and elements Yes Is there voltage across element loops at the convention elements Replace faulty contactor s Are all element loops drawing current Replace faulty element assembly No Yes...

Страница 67: ...nuity from end to end on all CAN cable wires Reconnect the cable making a good electrical connection Does the problem persist Replace the faulty CAN cable and retest The appliance should operate prope...

Страница 68: ...is missing and correct Is the grease collection pump running Yes Remove pump and clear obstruction between condensate pan and pump or between pump and grease collection bin No Activate grease collect...

Страница 69: ...e connected to a chemical jug Connect the hose to the chemical jug and retest Is there chemical inside the chemical jug Replace the chemical jug and retest No Yes Is the hose between the pump and the...

Страница 70: ...e smoke relay Repair the wiring issue between terminal 12 on the smoke relay and the terminal block 45 pin 5 Is L2 being supplied to smoke relay pin 8 Replace the faulty smoke relay No Yes Is there li...

Страница 71: ...Turn on the untreated water supply line Is there line voltage across the Y2 solenoid Determine which leg is missing and correct Is the Y2 solenoid opening Replace the faulty solenoid No Yes Is there w...

Страница 72: ...the rinse flow control valve clean of debris Is water at the injection pipe of the appliance Clean or repair water manifold and or hose from manifold to the injection pipe No Yes Is the injection pip...

Страница 73: ...ning water at the injection pipe Remove the obstruction between the water manifold and the injection pipe No Yes Is the injection pipe clear of debris The cleaning pump and plumbing circuit are workin...

Страница 74: ...ximately 10 15 seconds after B2 Does the Y1 solenoid de energize Investigate for scale build up inside the tank around the water level probes and or faulty water level probe assembly No Yes No Yes No...

Страница 75: ...s Replace the faulty contactor s No Yes No Yes No Yes See the Convection Fan Motor is Not Spinning No Yes Troubleshoot the boiler not filling No A1 is L1 supplied to the K1 boiler element contactor fr...

Страница 76: ...ulty contactor s No Yes No Yes No Yes See the Convection Fan Motor is Not Spinning No Yes Troubleshoot the boiler not filling No A1 is L1 supplied to the K1 boiler element contactor from Control Board...

Страница 77: ...e terminal block 27 1 and the power supply terminal N No Yes No Yes No Yes No Yes Inspect and or reset the circuit breaker No Replace the faulty power supply No Yes Is there 12 VDC across Control Boar...

Страница 78: ...e terminal block 27 1 and the power supply terminal N No Yes No Yes No Yes No Yes Inspect and or reset the circuit breaker No Replace the faulty power supply No Yes Is there 12 VDC across Control Boar...

Страница 79: ...being energized Yes Determine which line is missing at the solenoid No Yes Is the Y1 solenoid valve opening Repair the wiring issue between the main terminal blocks 1 1 6 1 11 1 and the K41 contactors...

Страница 80: ...r No Yes Is there line voltage across the black blue brown wires at the convection motor Repair the wiring issue between the K51 contactor and the convection motor No Is the K51 contactor closing Is t...

Страница 81: ...oss the red white yellow wires at the convection motor Replace the faulty contactor No Yes No Yes Remove the obstruction and or replace the motor as needed Determine which leg of power is missing and...

Страница 82: ...r No Yes Is there line voltage across the black blue brown wires at the convection motor Repair the wiring issue between the K51 contactor and the convection motor No Is the K51 contactor closing Is t...

Страница 83: ...d Yes Is there 120V across terminals 12 and 4 on the ignition control Determine which leg of power is missing and correct Replace the rectifier Terminal 12 is L1 and is supplied from terminal block 33...

Страница 84: ...pinning Is the N6 oven temperature probe below the set point Appliance is heating properly The convection element contactors will not be energized until the N6 oven temperature probe is below the set...

Страница 85: ...motor spinning Is the N6 oven temperature probe below the set point Is the burner igniting The appliance is heating properly No Yes See High Speed Convection Motor is Not Spinning No Yes No Yes Troubl...

Страница 86: ...No Yes No Yes The appliance will not call for steam production until the B5 probe is below the set point If the B5 probe is reading incorrectly test the probe and replace if necessary No Inspect clean...

Страница 87: ...opening No Yes Replace the faulty solenoid Is water going through the flow control valve Inspect clean replace the flow control valve as necessary No Yes Is water being injected into the fan wheel ins...

Страница 88: ...rectly test the probe and replace if necessary No Inspect clean replace the flow control valve as necessary No Yes Is water being injected into the fan wheel inside the appliance No Is the burner igni...

Страница 89: ...injected into the fan wheel inside the appliance No Yes Yes The appliance will not call for steam production until the N6 probe is below the set point If the N6 probe is reading incorrectly test the p...

Страница 90: ...mly reattach the CAN cable Replace the CAN cable Replace the CB Replace the IB Call Alto Shaam Service No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Disconnect the VFD communication cabl...

Страница 91: ...opulated on the board Is voltage supplied to the VFD on terminal S105 L1 L2 Yes Yes Is the LED on the VFD illuminated Add or remove the jumper and retest Populate and retest Check the fuses for contin...

Страница 92: ...eel Unlock the fan wheel The root cause of overheating must be determined call Alto Shaam Service for assistance The root cause of overheating must be determined call Alto Shaam Service for assistance...

Страница 93: ...t Replace the fan wheel Unlock the fan wheel The root cause of overheating must be determined call Alto Shaam Service for assistance The root cause of overheating must be determined call Alto Shaam Se...

Страница 94: ...94 MN 35949 Rev 04 06 16 Combitherm CT PROformance Series Technical Service Manual This page intentionally left blank...

Страница 95: ...110 Convection System 6 10 10 10 7 20 10 20 380V 3PH Touch 111 Convection System 20 10 380V 3PH Touch 112 Convection System 20 20 380V 3PH Touch 113 Convection System 6 10 10 10 7 20 10 20 440V 3PH T...

Страница 96: ...53 WI 33478 CR 34783 CB X02 4 CB X02 5 CR 34783 66 WI 33478 CR 34783 CB X07 2 IB X07 1 CR 34783 67 WI 33777 CR 34783 CB X07 3 IB X07 3 CR 34783 5015379 4W WI STOCK T CONN FROM TERM LOC TO TERM LOC L...

Страница 97: ...00 7W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 424 WI 33777 CR 34783 TB27 9 TB45 1 CR 34783 430 WI 33478 CR 34783 TB33 19 OB X01 1 CR 34783 440 WI 33478 CR 34783 TB33 11 OB X03 1 CR 34783 443...

Страница 98: ...34639 81 WI 33777 CR 34783 TB46 6 HANDSHOWER R SW 2 CR 34639 5016379 W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 21 WI 33478 CR 34783 TB33 1 LS1 1 CR 33509 22 WI 33478 CR 34783 TB38 1 LS1 2 CR...

Страница 99: ...3 F6 1 S1 L2 UPPR CR 34783 7 WI 33777 CR 34783 F10 1 S1 LWR CR 34783 8 WI 33478 CR 34783 F7 1 RLY50 12 000000 CR 38389 9 WI 33478 CR 34783 F11 1 RLY51 12 000000 CR 38389 10 WI 33776 CR 34783 TB50 1 S1...

Страница 100: ...3815 CR 34782 F4 2 F9 2 CR 34782 30 WI 3815 CR 34782 F6 2 F10 2 CR 34782 31 WI 3815 CR 34782 F7 2 F11 2 CR 34782 32 WI 33478 CR 34783 K50 1 K51 1 CR 34783 33 WI 33478 CR 34783 K50 3 K51 3 CR 34783 34...

Страница 101: ...6 IGNTR LWR CR 33509 201 WI 33777 CR 34783 TB 27 6 IGNTR N CR 36869 206 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 207 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 204 WI 33777 CR 33509 N7 11 TB27 8 CR 34...

Страница 102: ...0 7 CR 34783 5015355 7W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 200 WI 33478 CR 34783 TB33 6 IGNTR LWR CR 33509 201 WI 33777 CR 34783 TB 27 6 IGNTR N CR 36869 206 WI 33777 CR 33509 N7 31 CB X...

Страница 103: ...TERM LOC TO TERM LOC L CONN 45 WI 3816 CR 34781 TB1 2 K1 2 CR 34775 46 WI 3816 CR 34781 TB6 2 K1 4 CR 34775 48 WI 3816 CR 34781 TB1 2 K2 2 CR 34775 50 WI 3816 CR 34781 TB6 2 K2 4 CR 34775 54 WI 33777...

Страница 104: ...11 TB27 18 CR 34783 340 WI 33776 CR 33509 SG1 GND SG2 GND CR 34774 341 WI 33776 CR 34774 SG3 GND SG2 GND CR 33509 342 WI 33776 CR 33509 SG3 GND TB51 3 CR 34783 66 WI 33777 CR 33509 N9 12 K3 A2 CR 3838...

Страница 105: ...K2 5 CR 34775 306 WI 33777 CR 38389 K1 21 N9 11 CR 34774 307 WI 33478 CR 38389 K1 A1 K2 A1 CR 38389 308 WI 33777 CR 33509 N7 12 K1 22 CR 38389 309 WI 33777 CR 38389 K1 A2 K2 A2 CR 38389 339 WI 33777 C...

Страница 106: ...K2 A2 CR 38389 308 WI 3816 CR 34781 TB2 1 K2 1 CR 34775 309 WI 3816 CR 34781 TB7 1 K2 3 CR 34775 310 WI 3816 CR 34781 TB12 1 K2 5 CR 34775 316 WI 33777 CR 33509 N9 11 TB27 18 CR 34783 341 WI 33776 CR...

Страница 107: ...LOC L CONN 60 WI 3816 CR 34781 TB1 1 K41 2 CR 34781 61 WI 3816 CR 34781 TB6 1 K41 4 CR 34781 68 WI 33777 CR 38389 K41 A2 K44 A2 CR 38389 69 WI 3816 CR 34781 TB1 1 K44 2 CR 34781 71 WI 3816 CR 34781 K4...

Страница 108: ...CR 34781 K41 1 CH1 1 2 CR 38575 71 WI 3816 CR 34781 K41 3 CH1 1 1 CR 38575 72 WI 3816 CR 34781 K41 3 CH1 2 1 CR 38575 73 WI 3816 CR 34781 K41 5 CH1 2 2 CR 38575 74 WI 3816 CR 34781 K41 5 CH1 3 1 CR 38...

Страница 109: ...2 K43 A2 CR 38389 101 WI 3816 CR 34781 K44 5 CH1 3 2 CR 38575 103 WI 3816 CR 34781 K44 1 CH1 3 1 CR 38575 104 WI 3816 CR 34781 K44 3 CH2 3 1 CR 38575 105 WI 3816 CR 34781 K44 5 CH2 3 2 CR 38575 116 WI...

Страница 110: ...81 97 WI 3816 CR 34781 TB12 1 F51 2 CR 34781 97 WI 3816 CR 34781 TB12 1 F51 2 CR 34781 98 WI 3816 CR 34781 K44 2 F49 1 CR 34781 98 WI 3816 CR 34781 K44 2 F49 1 CR 34781 99 WI 3816 CR 34781 K44 4 F50 1...

Страница 111: ...83 105 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 106 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 5015371 W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 60 WI 3816 CR 34781 TB1 1 K77 2 CR 34781 60 WI...

Страница 112: ...8 N7 12 CR 33509 117 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 118 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 120 WI 3816 CR 34781 K41 1 CH1 1 1 CR 38575 121 WI 3816 CR 34781 K41 3 CH2 1 1 CR 38575 122...

Страница 113: ...8575 90 WI 3816 CR 34781 K43 3 CH2 4 1 CR 38575 91 WI 3816 CR 38575 CH1 4 2 TB17 1 CR 34781 92 WI 3816 CR 38575 CH2 4 2 TB17 1 CR 34781 93 WI 33777 CR 38389 K43 A2 K44 A2 CR 38389 94 WI 3816 CR 34781...

Страница 114: ...3509 93 WI 33777 CR 34783 CB X10 8 N7 31 CR 33509 94 WI 33777 CR 34783 CB X10 7 N7 32 CR 33509 95 WI 3816 CR 34781 TB3 1 F43 1 CR 34781 95 WI 3816 CR 34781 TB3 1 F43 1 CR 34781 96 WI 3816 CR 34781 TB8...

Страница 115: ...CR 38575 94 WI 33777 CR 38389 K44 A2 K43 A2 CR 38389 101 WI 3816 CR 34781 K44 5 CH1 3 2 CR 38575 103 WI 3816 CR 34781 K44 1 CH1 3 1 CR 38575 104 WI 3816 CR 34781 K44 3 CH2 3 1 CR 38575 105 WI 3816 CR...

Страница 116: ...CR 38389 K44 A2 K43 A2 CR 38389 95 WI 3816 CR 34781 TB2 1 F49 2 CR 34781 95 WI 3816 CR 34781 TB2 1 F49 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F50 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F50 2 CR 34781 97...

Страница 117: ...OM TERM LOC TO TERM LOC L CONN 409 WI 33478 CR 34782 TB2 2 F13 2 CR 34782 410 WI 33462 CR 34782 F13 1 CC_EL 1 CR 33509 411 WI 33478 CR 38389 CC_RLY 14 OB X01 4 CR 34783 412 WI 33777 CR 38389 CC_RLY 13...

Страница 118: ...o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77623 used on units after 7 31 15 77623 SIMPLE INTERFACE BOARD AFT 07 27 15 23 OF 42 Wiring Diagram...

Страница 119: ...o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 1 9 77623 used on units after 7 31 15 Wiring Diagram 77623 77623 TOUCH INTERFACE BOARD AFT 07 27...

Страница 120: ...TO TERM LOC L CONN 464 WI 33478 CR 34783 TB33 18 PSSW COMMON CR 34774 465 WI 33478 CR 33509 FLTSW1 1 PSSW COMMON CR 33509 466 WI 33777 CR 34783 OB X04 1 PSSW NORMAL OPEN CR 33509 467 WI 33478 CR 33509...

Страница 121: ...6 1 6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 2 1 77623 used on units after 7 31 15 Wiring Diagram 77623 77623 Floor Model Chassis AFT 0...

Страница 122: ...6 1 6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77623 used on units after 7 31 15 77623 7 14 ES 380V LEGEND AFT 07 27 15 27 OF 42 Wiring Dia...

Страница 123: ...i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 2 3 77623 used on units after 7 31 15 Wiring Diagram 77623 77623 6 10 10 10 7 14 ELEMENT PINS LAYOUT AFT...

Страница 124: ...1 6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77623 used on units after 7 31 15 77623 EL 35518 10 18 LEGEND AFT 07 27 15 29 OF 42 Wiring Di...

Страница 125: ...o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 2 5 77623 used on units after 7 31 15 Wiring Diagram 77623 77623 EL 35518 20 20 LEGEND AFT 07 27...

Страница 126: ...o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77623 used on units after 7 31 15 77623 BLOCK DIAGRAM AFT 07 27 15 31 OF 42 12Vdc M 12Vdc M Wiring...

Страница 127: ...WI 33478 CR 34783 K61 4 MOTOR LWR CON CR 34783 25 WI 33478 CR 34783 K61 6 MOTOR LWR CON CR 34783 26 WI 33777 CR 34783 K50 A2 K51 A2 CR 34783 27 WI 33777 CR 34783 K51 A2 K60 A2 CR 34783 28 WI 33777 CR...

Страница 128: ...81 K41 5 CH1 3 1 CR 38575 73 WI 33777 CR 38389 K41 A2 N7 11 CR 33509 81 WI 33777 CR 33509 N7 12 TB27 18 CR 34783 82 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 83 WI 33777 CR 33509 N7 32 CB X10 7 CR 347...

Страница 129: ...81 K41 6 F42 2 CR 34781 68 WI 3816 CR 34781 F45 2 K44 6 CR 34781 68 WI 3816 CR 34781 F45 2 K44 6 CR 34781 69 WI 3816 CR 34781 K41 1 CH1 3 2 CR 38575 70 WI 3816 CR 34781 K41 1 CH1 1 2 CR 38575 71 WI 38...

Страница 130: ...781 K41 3 CH1 2 1 CR 38575 71 WI 3816 CR 34781 K41 5 CH1 2 2 CR 38575 72 WI 3816 CR 34781 K41 5 CH1 3 1 CR 38575 79 WI 33478 CR 38389 K41 A1 K43 A1 CR 38389 80 WI 33777 CR 38389 K41 A2 K43 A2 CR 38389...

Страница 131: ...3816 CR 34781 TB12 1 F45 2 CR 34781 98 WI 3816 CR 34781 K44 2 F43 1 CR 34781 99 WI 3816 CR 34781 K44 4 F44 1 CR 34781 100 WI 3816 CR 34781 K44 6 F45 1 CR 34781 101 WI 3816 CR 34781 K44 1 CH2 3 2 CR 38...

Страница 132: ...CR 34781 60 WI 3816 CR 34781 TB1 1 K77 2 CR 34781 61 WI 3816 CR 34781 TB6 1 K77 4 CR 34781 61 WI 3816 CR 34781 TB6 1 K77 4 CR 34781 62 WI 3816 CR 34781 TB11 1 K77 6 CR 34781 62 WI 3816 CR 34781 TB11...

Страница 133: ...1 K41 2 CR 34781 70 WI 3816 CR 34775 F41 1 K41 4 CR 34781 71 WI 3816 CR 34775 F42 1 K41 6 CR 34781 74 WI 3816 CR 34781 K41 1 CH1 1 1 CR 38575 75 WI 3816 CR 34781 K41 3 CH1 2 1 CR 38575 76 WI 3816 CR...

Страница 134: ...6 CR 38575 CH1 5 2 CH1 4 2 CR 38575 81 WI 3816 CR 38575 CH1 5 2 CH1 6 2 CR 38575 82 WI 33478 CR 34783 TB35 10 K77 A1 CR 38389 83 WI 33777 CR 38389 K77 A2 N7 11 CR 33509 85 WI 33478 CR 38389 K41 A1 K43...

Страница 135: ...I 3816 CR 34781 TB11 1 F42 1 CR 34781 62 WI 3816 CR 34781 TB11 1 F42 1 CR 34781 63 WI 3816 CR 34781 K41 2 F40 2 CR 34781 63 WI 3816 CR 34781 K41 2 F40 2 CR 34781 64 WI 3816 CR 34781 F43 2 K44 2 CR 347...

Страница 136: ...38575 71 WI 3816 CR 34781 K41 5 CH1 2 2 CR 38575 72 WI 3816 CR 34781 K41 5 CH1 3 1 CR 38575 79 WI 33478 CR 38389 K41 A1 K43 A1 CR 38389 80 WI 33777 CR 38389 K41 A2 K43 A2 CR 38389 90 WI 3816 CR 34781...

Страница 137: ...81 TB2 1 F43 2 CR 34781 95 WI 3816 CR 34781 TB2 1 F43 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F44 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F44 2 CR 34781 97 WI 3816 CR 34781 TB12 1 F45 2 CR 34781 97 WI 3816...

Страница 138: ...8 M N 3 5 9 4 9 R e v 0 4 0 6 1 6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77623 used on units after 7 31 15 This page intentionally left b...

Страница 139: ...ion System 6 10 10 10 7 20 10 20 380V 3PH Touch 155 Convection System 20 10 380V 3PH Touch 156 Convection System 20 20 380V 3PH Touch 157 Convection System 6 10 10 10 7 20 10 20 440V 3PH Touch 158 Con...

Страница 140: ...O TERM LOC L CONN 52 WI 33478 CR 34783 CB X02 5 TB35 6 CR 34783 66 WI 33478 CR 34783 CB X07 2 IB X07 1 CR 34783 67 WI 33777 CR 34783 CB X07 3 IB X07 3 CR 34783 5015379 4W WI STOCK T CONN FROM TERM LOC...

Страница 141: ...AFT 04 12 12 2 OF 42 5016400 4W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 424 WI 33777 CR 34783 TB27 9 TB45 1 CR 34783 430 WI 33478 CR 34783 TB35 11 OB X01 1 CR 34783 440 WI 33478 CR 34783 TB35...

Страница 142: ...CR 3593 RLY60 12 Y5 A2 CR 33509 78 WI 33777 CR 3593 RLY60 8 TB27 15 CR 34783 79 WI 33478 CR 34783 TB42 7 RLY60 14 CR 3593 80 WI 33777 CR 3593 RLY60 13 HANDSHOW ER R SW 1 CR 33509 81 WI 33777 CR 34783...

Страница 143: ...LY51 9 CR 3593 6 WI 33777 CR 34783 F6 1 S1 L2 UPPR CR 34783 7 WI 33777 CR 34783 F10 1 S1 LWR CR 34783 8 WI 33478 CR 34783 F7 1 RLY50 12 CR 3593 9 WI 33478 CR 34783 F11 1 RLY51 12 CR 34783 10 WI 33776...

Страница 144: ...28 WI 33777 CR 34783 K60 A2 K61 A2 CR 34783 29 WI 3815 CR 34782 F4 2 F9 2 CR 34782 30 WI 3815 CR 34782 F6 2 F10 2 CR 34782 31 WI 3815 CR 34782 F7 2 F11 2 CR 34782 32 WI 33478 CR 34783 K50 1 K51 1 CR 3...

Страница 145: ...3 6 IGNTR LWR CR 33509 201 WI 33777 CR 34783 TB 27 6 IGNTR N CR 36869 206 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 207 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 204 WI 33777 CR 33509 N7 11 TB27 8 CR...

Страница 146: ...77 CR 33509 N7 32 CB X10 7 CR 34783 5015355 6W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 200 WI 33478 CR 34783 TB33 6 IGNTR LWR CR 33509 201 WI 33777 CR 34783 TB 27 6 IGNTR N CR 36869 206 WI 33...

Страница 147: ...FROM TERM LOC TO TERM LOC L CONN 45 WI 3816 CR 34781 TB1 2 K1 2 CR 34775 46 WI 3816 CR 34781 TB6 2 K1 4 CR 34775 48 WI 3816 CR 34781 TB1 2 K2 2 CR 34775 50 WI 3816 CR 34781 TB6 2 K2 4 CR 34775 54 WI 3...

Страница 148: ...61 WI 33777 CR 33509 N9 11 TB27 16 CR 3593 340 WI 33776 CR 33509 SG1 GND SG2 GND CR 34774 341 WI 33776 CR 34774 SG3 GND SG2 GND CR 33509 342 WI 33776 CR 33509 SG3 GND TB51 3 CR 34783 66 WI 33777 CR 3...

Страница 149: ...TB11 2 K2 5 CR 34775 306 WI 33777 CR 3593 K1 21 N9 11 CR 34774 307 WI 33478 CR 3593 K1 A1 K2 A1 CR 3593 308 WI 33777 CR 33509 N7 12 K1 22 CR 3593 309 WI 33777 CR 3593 K1 A2 K2 A2 CR 3593 339 WI 33777...

Страница 150: ...WI 33777 CR 3593 K1 A2 K2 A2 CR 3593 308 WI 3816 CR 34781 TB2 1 K2 1 CR 34775 309 WI 3816 CR 34781 TB7 1 K2 3 CR 34775 310 WI 3816 CR 34781 TB12 1 K2 5 CR 34775 316 WI 33777 CR 33509 N9 11 TB27 18 CR...

Страница 151: ...TERM LOC L CONN 60 WI 3816 CR 34781 TB1 1 K41 2 CR 34781 61 WI 3816 CR 34781 TB6 1 K41 4 CR 34781 68 WI 33777 CR 3593 K41 A2 K44 A2 CR 3593 69 WI 3816 CR 34781 TB1 1 K44 2 CR 34781 71 WI 3816 CR 3478...

Страница 152: ...K41 1 CH1 3 2 CR 3071 70 WI 3816 CR 34781 K41 1 CH1 1 2 CR 3071 71 WI 3816 CR 34781 K41 3 CH1 1 1 CR 3071 72 WI 3816 CR 34781 K41 3 CH1 2 1 CR 3071 73 WI 3816 CR 34781 K41 5 CH1 2 2 CR 3071 74 WI 3816...

Страница 153: ...4 A2 K43 A2 CR 3593 101 WI 3816 CR 34781 K44 5 CH1 3 2 CR 33008 103 WI 3816 CR 34781 K44 1 CH1 3 1 CR 33008 104 WI 3816 CR 34781 K44 3 CH2 3 1 CR 33008 105 WI 3816 CR 34781 K44 5 CH2 3 2 CR 33008 116...

Страница 154: ...TB7 1 F50 2 CR 34781 97 WI 3816 CR 34781 TB12 1 F51 2 CR 34781 97 WI 3816 CR 34781 TB12 1 F51 2 CR 34781 98 WI 3816 CR 34781 K44 2 F49 1 CR 34781 98 WI 3816 CR 34781 K44 2 F49 1 CR 34781 99 WI 3816 C...

Страница 155: ...105 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 106 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 5015371 5W WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 60 WI 3816 CR 34781 TB1 1 K77 2 CR 34781 60 WI...

Страница 156: ...33777 CR 3593 K44 A2 N7 11 CR 34774 116 WI 33777 CR 3593 TB27 18 N7 12 CR 33509 117 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 118 WI 33777 CR 33509 N7 32 CB X10 7 CR 34783 120 WI 3816 CR 34781 K41 1...

Страница 157: ...816 CR 3071 CH1 4 2 TB17 1 CR 34781 92 WI 3816 CR 3071 CH2 4 2 TB17 1 CR 34781 93 WI 33777 CR 3593 K43 A2 K44 A2 CR 3593 94 WI 3816 CR 34781 K78 1 F48 2 CR 34775 95 WI 3816 CR 34781 K78 3 F47 2 CR 347...

Страница 158: ...3 TB27 18 N7 12 CR 33509 93 WI 33777 CR 34783 CB X10 8 N7 31 CR 33509 94 WI 33777 CR 34783 CB X10 7 N7 32 CR 33509 95 WI 3816 CR 34781 TB3 1 F43 1 CR 34781 95 WI 3816 CR 34781 TB3 1 F43 1 CR 34781 96...

Страница 159: ...K43 A2 CR 3593 101 WI 3816 CR 34781 K44 5 CH1 3 2 CR 33008 103 WI 3816 CR 34781 K44 1 CH1 3 1 CR 33008 104 WI 3816 CR 34781 K44 3 CH2 3 1 CR 33008 105 WI 3816 CR 34781 K44 5 CH2 3 2 CR 33008 116 WI 3...

Страница 160: ...H2 4 2 CR 3071 94 WI 33777 CR 3593 K44 A2 K43 A2 CR 3593 95 WI 3816 CR 34781 TB2 1 F49 2 CR 34781 95 WI 3816 CR 34781 TB2 1 F49 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F50 2 CR 34781 96 WI 3816 CR 34781...

Страница 161: ...NN FROM TERM LOC TO TERM LOC L CONN 409 WI 33478 CR 34782 TB2 2 F13 2 CR 34782 410 WI 33462 CR 34782 F13 1 CC_EL 1 CR 33509 411 WI 33478 CR 3593 CC_RLY 14 OB X01 4 CR 34783 412 WI 33777 CR 3593 CC_RLY...

Страница 162: ...C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 SIMPLE INTERFACE BOARD AFT 04 1...

Страница 163: ...m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 6 3 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 TOUCH INTERFACE BOARD AFT 04 1...

Страница 164: ...WI STOCK T CONN FROM TERM LOC TO TERM LOC L CONN 464 WI 33478 CR 34783 TB35 8 PSSW 1 CR 34774 465 WI 33478 CR 33509 FLTSW1 1 PSSW 1 CR 33509 466 WI 33777 CR 34783 OB X04 1 PSSW 2 CR 33509 467 WI 33478...

Страница 165: ...m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 6 5 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 Floor Model Chassis AFT 04 12...

Страница 166: ...6 1 6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 7 14 ES 380V LEGEND AFT 04...

Страница 167: ...h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 6 7 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 6 10 10 10 7 14 ELEMENT PINS LAYOUT AF...

Страница 168: ...6 C o m b i t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 EL 35518 10 18 LEGEND AFT 04 1...

Страница 169: ...t h e r m C T P R O f o r m a n c e S e r i e s T e c h n i c a l S e r v i c e M a n u a l 1 6 9 77529 used on units previous to 8 1 15 Wiring Diagram 77529 77529 EL 35518 20 20 LEGEND AFT 04 12 12 3...

Страница 170: ...783 24 WI 33478 CR 34783 K61 4 MOTOR LWR CON CR 34783 25 WI 33478 CR 34783 K61 6 MOTOR LWR CON CR 34783 26 WI 33777 CR 34783 K50 A2 K51 A2 CR 34783 27 WI 33777 CR 34783 K51 A2 K60 A2 CR 34783 28 WI 33...

Страница 171: ...33008 305 WI 3816 CR 34781 K41 5 CH1 3 1 CR 33008 73 WI 33777 CR 3593 K41 A2 N7 11 CR 33509 81 WI 33777 CR 33509 N7 12 TB27 18 CR 34783 82 WI 33777 CR 33509 N7 31 CB X10 8 CR 34783 83 WI 33777 CR 335...

Страница 172: ...CR 34781 K41 6 F42 2 CR 34781 68 WI 3816 CR 34781 F45 2 K44 6 CR 34781 68 WI 3816 CR 34781 F45 2 K44 6 CR 34781 69 WI 3816 CR 34781 K41 1 CH1 3 2 CR 33008 70 WI 3816 CR 34781 K41 1 CH1 1 2 CR 33008 71...

Страница 173: ...6 CR 34781 K41 3 CH1 2 1 CR 33008 71 WI 3816 CR 34781 K41 5 CH1 2 2 CR 33008 72 WI 3816 CR 34781 K41 5 CH1 3 1 CR 33008 79 WI 33478 CR 3593 K41 A1 K43 A1 CR 3593 80 WI 33777 CR 3593 K41 A2 K43 A2 CR 3...

Страница 174: ...7 WI 3816 CR 34781 TB12 1 F45 2 CR 34781 98 WI 3816 CR 34781 K44 2 F43 1 CR 34781 99 WI 3816 CR 34781 K44 4 F44 1 CR 34781 100 WI 3816 CR 34781 K44 6 F45 1 CR 34781 101 WI 3816 CR 34781 K44 1 CH2 3 2...

Страница 175: ...N 60 WI 3816 CR 34781 TB1 1 K77 2 CR 34781 60 WI 3816 CR 34781 TB1 1 K77 2 CR 34781 61 WI 3816 CR 34781 TB6 1 K77 4 CR 34781 61 WI 3816 CR 34781 TB6 1 K77 4 CR 34781 62 WI 3816 CR 34781 TB11 1 K77 6 C...

Страница 176: ...775 F40 1 K41 2 CR 34781 70 WI 3816 CR 34775 F41 1 K41 4 CR 34781 71 WI 3816 CR 34775 F42 1 K41 6 CR 34781 74 WI 3816 CR 34781 K41 1 CH1 1 1 CR 33008 75 WI 3816 CR 34781 K41 3 CH1 2 1 CR 33008 76 WI 3...

Страница 177: ...43 5 CH1 6 1 CR 33008 80 WI 3816 CR 33008 CH1 5 2 CH1 4 2 CR 33008 81 WI 3816 CR 33008 CH1 5 2 CH1 6 2 CR 33008 82 WI 33478 CR 34783 TB35 10 K77 A1 CR 3593 83 WI 33777 CR 3593 K77 A2 N7 11 CR 33509 85...

Страница 178: ...CR 34781 62 WI 3816 CR 34781 TB11 1 F42 1 CR 34781 62 WI 3816 CR 34781 TB11 1 F42 1 CR 34781 63 WI 3816 CR 34781 K41 2 F40 2 CR 34781 63 WI 3816 CR 34781 K41 2 F40 2 CR 34781 64 WI 3816 CR 34781 F43 2...

Страница 179: ...6 CR 34781 K41 3 CH1 2 1 CR 33008 71 WI 3816 CR 34781 K41 5 CH1 2 2 CR 33008 72 WI 3816 CR 34781 K41 5 CH1 3 1 CR 33008 79 WI 33478 CR 3593 K41 A1 K43 A1 CR 3593 80 WI 33777 CR 3593 K41 A2 K43 A2 CR 3...

Страница 180: ...2 1 F43 2 CR 34781 95 WI 3816 CR 34781 TB2 1 F43 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F44 2 CR 34781 96 WI 3816 CR 34781 TB7 1 F44 2 CR 34781 97 WI 3816 CR 34781 TB12 1 F45 2 CR 34781 97 WI 3816 CR 34...

Страница 181: ......

Страница 182: ...rio Canada Toll Free Phone 866 577 4484 Phone 1 905 660 6781 Alto Shaam Central South America Miami FL USA Phone 1 954 655 5727 Alto Shaam Middle East Africa Dubai UAE Phone 971 4 321 9712 Alto Shaam...

Отзывы: