MN-37010 (Rev. 8) 03/18 • Arby’s 300-TH/III Touch
•
30
Service
Exterior View - Top
26
18
23
23
5
16
19
21
20
24
15
17
7
10
1
8
9
4
3
11
6
2
22
12
13
14
26
18
23
23
5
16
19
21
20
24
15
17
7
10
1
8
9
4
3
11
6
2
22
12
13
14
Item Description
Part
Qty
1
RELAY, SOLID STATE, 230V, 25A
RL-33829 1
2
BUZZER ASSY, WITH CONNECTOR
5018422
1
3
SCREW, PAN PH, METRIC, M5
SC-36973 1
4
BOARD, POWER SUPPLY, 12V
BA-38586 1
5
SCREW, M3 x 0.5 x 8mm PAN
SC-22268 2
6
FAN, 3" BOX 120V
230V
FA-3973
FA-34524
1
1
7
SCREW, M4 x 0.7 x 45mm PAN
SC-28142 2
HI-LIMIT PROTECTION COVER
1003936
1
9
SCREW, M4 x 0.7 x 6mm PAN
SC-22271 2
10
THERMOSTAT, 300°F HI-LIMIT
TT-33476 1
11
T-BLOCK
BK-3019
1
12
SCREW, M4 x 0.7 x 30mm PAN
SC-29276 2
13
CONNECTOR, USB, PANEL MOUNT
CB-35746 1
Item Description
Part
Qty
14
SWITCH, ROCKER, 125-277V, 20A
SW-34769 1
15
SPACER, SUPPORT, NYLON 1.4"
SP-33707 5
16
SPACER, 7/16" NYLON
SP-33901 5
17
CABLE, FLAT RIBBON, 28", 10 WIRE
CB-36986 1
18
CAP, DUST, CONNECTOR, PLASTIC
CP-36970 1
19
CONNECTOR, DSUB, FEMALE 9 PIN
CR-36971 1
20
SERIAL CABLE MOUNTING BOX
1018249
1
21
CABLE, ASSEMBLY
5018092
1
22
BUSHING, STRAIN RELIEF, 90°
BU-34898 1
23
SPOT ASSEMBLY, COMM BOX
5018093
1
24
SCREW, M3 x 0.5 x 8mm PAN
SC-22268 2
26
SITESAGE, CONTROL KIT
5019895
1
8
Part numbers and drawings are subject to change without notice.
WARNING
To prevent serious injury, death, or property
damage,
always disconnect the appliance
from the power source before cleaning
or servicing.
DANGER
To prevent serious injury, death, or property
damage,
always lock‑out or post breaker
panel until service work has been completed.