Electrical Information
The appliance must be installed by a qualified service
technician. The oven must be properly grounded
in accordance with the National Electrical Code and
applicable local codes.
Plug the unit into a properly grounded receptacle only,
positioning the unit so that the plug is easily accessible in
case of an emergency. Arcing will occur when connecting
or disconnecting the unit unless all controls are in the
“Off” position.
Proper receptacle or outlet configuration or permanent
wiring for this unit must be installed by a licensed
electrician in accordance with applicable local electrical
codes.
Regarding international standard units:
If the unit is not equipped with flexible cord and plug, an
all-pole country approved disconnection device which
has a contact separation of at least 3mm in all poles must
be incorporated in the fixed wiring for disconnection.
When using a cord without a plug, the green/yellow
conductor shall be connected to the terminal which is
marked with the ground symbol. If a plug is used, the
socket outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained from the
distributor.
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
WARNING
To prevent serious injury, death, or
property damage:
All electrical connections must be
made by a qualified and trained service
technician in accordance with applicable
electrical codes.
This appliance must be adequately
grounded in accordance with local
electrical codes or, in the absence of local
codes, with the current edition of the
National Electrical Code ANSI/NFPA No.
70. In Canada, all electrical connections
are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1 or
local codes.
CE‑approved appliances include an
equipotential‑bonding terminal marked
with the symbol shown on the left .
Provisions for earthing are to be made in
accordance with IEC:2010 60335‑1 section
27 or local codes.
NOTICE:
Where local codes and CE regulatory
requirements apply, appliances must be
connected to an electrical circuit that is
protected by an external GFCI outlet.
Hard wired models
Hard wired models must be equipped with a country
certifi ed external allpole disconnection switch with
suffi cient contact separation. Hard wired models that are
mounted on casters must have a strain relief device (tether)
to prevent strain on the power supply cord. If a power cord
is used for the connection of the product an oil resistant
cord like H05RN or H07RN or equivalent must be used.
WARNING
Appliances without a cord provided by the
factory must be equipped with a cord of
suff icient length to permit the appliance to
be moved for cleaning.
Always use the correct AWG wire size
based on the electrical requirements for
the appliance.