2007, ALPHI Technology Corporation
2.2.2 CONTINUOUS
MODE
If continuous acquisition is desired, then the following procedure is used. Remember
that in a real world scenario, it is not possible to read the data at the maximum rate
that the IP is capable of. There is no way to predict the exact performance as it
depends on the carrier board and the application.
Setting the DATARAM pointer with a desired address lower than the End address or
a number of scan lower than the total scan and enabling an interrupt, the host can
“throttle” the read of A/D data.