Chapter 3: AT-SBx81CFC960 Controller Fabric Card
66
Section I: Hardware Overview
SYS Status LEDs
The SYS (System) Status LEDs on the controller fabric card display
general status information about the controller card, power supplies, and
fan module. The LEDs are defined in Table 17 on page 66.
Table 17. SYS (System) Status LEDs
LED
State
Description
CFC
Solid Green
Indicates that the AT-SBx81CFC960 Controller
Fabric Card is operating normally as the active
master controller card.
Flashing
Green
Indicates that the controller card is initializing its
management software or synchronizing its
database with the active master controller card.
Solid
Amber
Indicates that the controller card is operating
normally as the standby master controller card.
Flashing
Amber
Indicates that the controller card is disabled. An
active master controller card might disable a
standby master controller card if the two cards
have incompatible versions of the management
software and are unable to resolve the problem,
possibly because of insufficient free flash memory.
PSU
Solid Green
Indicates that the power supplies are operating
properly.
Flashing
Amber
Indicates that a power supply is experiencing a
problem. Possible causes are:
The input AC voltage from a power source is
not within the normal operating range of a
power supply module.
The output DC voltage from a power supply
module to the line cards is not within the
normal operating range.
A power supply is experiencing high
temperature.
A power supply has failed.
Check the status LEDs on the individual power
supply modules to determine which module has a
fault condition.
Содержание AT-SBx81CFC960
Страница 14: ...List of Tables 14...
Страница 20: ...20...
Страница 34: ...Chapter 1 Chassis and Power Supplies 34 Section I Hardware Overview...
Страница 80: ...80...
Страница 104: ...Chapter 5 Installing the Chassis in an Equipment Rack 104 Section II Installing the Chassis...
Страница 124: ...Chapter 6 Installing the Power Supplies 124 Section II Installing the Chassis...
Страница 262: ...Chapter 12 Replacing Modules 262 Section II Installing the Chassis...
Страница 270: ...Chapter 13 Upgrading the Controller Fabric Card 270 Section II Installing the Chassis...
Страница 272: ...272...
Страница 286: ...Chapter 14 VCStack Plus Overview 286 Section III Building a Stack with VCStack Plus...