53277
29
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31. FRONT AIR DUCT
Refer to Figure 23
a. Remove front panel. Refer to Paragraph 11.
b. Remove lint filter. Refer to Paragraph 20.
c. Remove two Phillips head and two hex head
screws holding air duct to front bulkhead and
lift off.
IMPORTANT: When reassembling air duct, be sure
felt seal goes over (around) metal flange on air duct.
32. EXHAUST DUCT
Refer to Figure 24
a. Disconnect electric power, vent (and gas line if
necessary) and move unit to gain access to rear
of dryer.
b. Remove screw holding exhaust duct bracket to
rear of cabinet and remove exhaust duct.
33. EXHAUST FAN COVER
Refer to Figure 24
a. Remove front panel. Refer to Paragraph 11.
b. Remove front air duct. Refer to Paragraph 31.
c. Disconnect wires from thermostats or
thermostat heater and thermostat.
NOTE: Refer to appropriate wiring diagram when
rewiring thermostats.
d. Remove screws holding fan cover to housing
Figure 23
DRY958S
RATCHET
WHEEL
SWITCH
LEVER
SWITCHES