42
53277
Section 6 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
50. INSTALLING THE NO. 458P3 KIT
a. Remove Phillips head screw (if present), or
unlock access door lock (if present), then apply
thumb pressure to the right side of access door.
Refer to Figure 38. When door opens, move
door to the left to disengage from door
supports.
b. Disconnect igniter wires at quick disconnect
blocks. Refer to Figure 40.
c. Remove hex head screw holding burner tube
and igniter in place. Refer to Figure 40.
d. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from gas valve.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
e. Turn burner orifice spud out of gas valve and
install No. 60418 L.P. Burner Orifice Spud
(metal stamped No. 53). Torque new burner
orifice spud to 30 inch-pounds (3.4 N-m).
f. Reinstall burner tube, tighten hex head screw
firmly and reconnect igniter leads.
g. Remove vent screw and install No. 58754
Block-Open Plug. Refer to Figure 41.
h. Install No. 60517 “Valve Converted to L.P.
Gas” Sticker to top side of gas valve so it covers
the gas valve part number. Refer to Figure 40.
Figure 40
1 - 3
4 5
DRY963S
OPEN
POSITION
CLOSED
POSITION
SHUTOFF VALVE
HANDLE
VENT
SCREW
IGNITER
QUICK DISCONNECT
BLOCKS
BURNER
TUBE
HEX HEAD
SCREW
BURNER
HOUSING
AIR
SHUTTER
PRESSURE TAP
PIPE PLUG
APPLY NO. 60517
VALVE CONVERTED
STICKER HERE
VENT
SCREW
BURNER
ORIFICE
SPUD
TOP VIEW OF
GAS VALVE
To reduce the risk of fire and explosion,
reach in through access door opening and
turn the gas line shut-off valve handle to
the closed position. Refer to Figure 33.
DANGER