Section 3 Grounding
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. NEUTRAL AT TERMINAL BLOCK TO
TERMINAL BLOCK BRACKET AND
FROM TERMINAL BRACKET TO
CONTROL (Electric Models Only)
Refer to Figure 3
4. POWER CORD TO TERMINAL BLOCK BRACKET AND FROM TERMINAL BLOCK BRACKET
TO CONTROL HOUSING. WALL RECEPTACLE POLARITY CHECK (Gas Models Only)
Refer to Figure 4
Figure 3
GROUND
WIRE
DRY834S
Figure 4
120
V.A.C.
120
V.A.C.
0
V.A.C.
GROUND
WIRE
DRY945S
GROUND
NEUTRAL
L1
NEUTRAL
SIDE
NOTE: For determining
the correct polarity of a
wall receptacle.