53277
13
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 4
Service Procedures
IMPORTANT: When reference to direction (right
or left) is made in this manual, it is from the
operator’s position facing the front of the dryer.
7. CONTROL PANEL
Refer to Figure 7
a. Unlock control panel.
b. Lift up on control panel and swing bottom of
control panel out, then pull down and away
from control cabinet.
8. ACCUMULATOR
Refer to Figure 8
a. Remove control panel. Refer to Paragraph 7.
b. Reach in through control panel opening and
remove screws holding accumulator and
mounting bracket to control cabinet.
c. Disconnect wires from accumulator.
NOTE: Refer to appropriate wiring diagram when
rewiring accumulator.
Figure 7
DRY948S
PUSH-TO-START
SWITCH
(Upper Dryer)
PUSH-TO-START
SWITCH
(Lower Dryer)
UNLOCK AND
LIFT UP
SWING
BOTTOM OUT
PULL DOWN
AND AWAY
FABRIC SELECTOR
SWITCH
(Upper Dryer)
FABRIC SELECTOR
SWITCH
(Lower Dryer)
Figure 8
ON
DRY449S
ACCUMULATOR
ATTACHING SCREWS