24
53277
Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
c. Igniter. Refer to Figure 18
(1) Remove burner tube and igniter, step “b”.
(2) If 55438 igniter, remove by carefully
spreading mounting clip with snap ring
pliers. Refer to Figure 18.
(3) If 58823 igniter, remove Phillips head
screw holding igniter and ceramic block to
burner tube. Refer to Figure 18.
NOTE: Igniters 55438 and 58823 are not
interchangeable.
Use care in removal so as not to damage or
break igniter as it is very fragile.
CAUTION
Handle igniter by grasping white ceramic
portions only. DO NOT handle silicon
carbide portion of igniter with hands or
allow any oil, grease or other foreign
material to contaminate it. Oil, grease and
other impurities or hairline cracks will cause
igniter to burn out.
WARNING
Figure 18
DRY952S
CARBORUNDUM
IGNITER AND
BRACKET
NORTON
IGNITER AND
BRACKET
ATTACHING
SCREW
ATTACHING
SCREW
58823
IGNITER AND
BRACKET