Страница 1: ...uctions This wilt simplify the installation and ensure the dryer is installed correctly and safely Leave these instructions near the Dryer after installation for future reference NOTE The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code ANS NEPA70 NOTE The gas service to the Dryer must conform with local codes and o...

Страница 2: ...ed at 240 volt AC minimum 30 amp with 3 open end spade lug connectors with upturned ends or closed loop connectors OR a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers If being installed in a manufactured mobile home the d...

Страница 3: ... well as increase drying times Do not screen the exhaust ends of the vent system nor use any screws or rivets to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct pipe fi...

Страница 4: ...7 cm pipe 3 If codes allow flexible metal tubing may be used to connect your dryer to the gas supply line The tubing MUST be constructed of stainless steel or plastic coated brass 4 Tile gas supply line MUST have an individual shutoff valve 5 A I 8 inch 0 32 cm N RT plugged tapping accessible for test gauge conne tion MUST be installed immediately upstream of the gas supply connection to the dryer...

Страница 5: ...e inches 387 square centimeters 3 inches 7 6 cm from bottom and top of door NOTE Under counter and stack models 0 inches 0 cm for sides rear and top This dryer MUST be exhausted outdoors 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation CLOSET DOOR ii _i i_ 0 0 cm ii i_ I 2 54 cm _ii_0 0 cm _ O Ocm I 15 38 1cm J I 2 54 cm I 0 0 ...

Страница 6: ...door handle 72 39cm 0 o L_ _ i D i I T i i I L 13 5 To rear base exhaus _2 375 1 O3cm 27 0 I 68 58cm Electrical supply on rear of unit 36 _ 91 44cm 34 29cm Stacked Dryer Installation Dimensions T 72 00 11 12cm 182 88cm 4 375 Side exhausts 41 00 104 14cm Cenier line height for rear right left vents ii 28 25 to front of cabinet 71 75cm 28 75 to clear knobs 73 03cm 29 5 to clear door handle 49 to cle...

Страница 7: ...SI Z 21_E1 or ANSVUL2158 CAN CSA C222 latest editions for HOME USE only_ Correct 1 Using the four shipping carton corner posts two on each side carefully Jay the dryer on its left side and remove the foam shipping base To prevent damage do not use the control panel as a means to pick up or move the dryer 2 Return the dryer to an upright position FOAM SHIPPING REVERSING DOOR SWING Your dryer is des...

Страница 8: ... door handle O Rotate the lens 180 degrees 1 Place the door handle through the lens and reattach using the screws removed in step 5 2 Insert the door handle hole plugs in the holes vacated by the screws removed in step 5 13 Remove the four screws that secure the door hinges to the door 4 Remove the 4 tie in screws from the side of the door 5 Using the 4 screws removed in step 4 reinstall the hinge...

Страница 9: ...cle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply 2 If your dryer is equipped with a power supply cord having an equipment grounding conductor and a grounding plug the plug MUST be plugged into an appropriate copper wired receptacle that is properly installed and groun...

Страница 10: ...rn 9 Reinstall the terminal block cover i 1 10 ELECTRICAL CONNECTIONS FOR 4 WIRE SYSTEM EL ECTR C Dryer Remove the screws securing the terminal block access cover and tile strain relief mounting bracket located on the back of the dryer upper corner Install a U L approved strain relief in the entry hole of the mounting bracket Finger tighten the nut only at this time Remove the ground wire from the...

Страница 11: ...oxes clothing etc obstructs the flow of combustion and ventilation air 5 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner oft If this happens turn the timer to OFF and w...