![Allen-Bradley 1783-WAPAK9 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/allen-bradley/1783-wapak9/1783-wapak9_user-manual_2900827049.webp)
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
49
Install the Stratix 5100 Wireless Access Point/Workgroup Bridge
Chapter 2
Checking Power
You can verify the availability of power to the access point/bridge by checking the
power injector
•
Power status indicator
–
Green color indicates input power is being supplied to the bridge.
–
Red color indicates an overcurrent or overvoltage error condition—
disconnect input power from the power injector, check all coax cable
connections for a possible short, wait approximately 1 minute, and
reconnect input power to the power injector. If the status indicator
turns red again, contact technical support for assistance.
Off indicates input power is not available—verify that the power module is
connected to the power injector and that AC power is available.
Operating status
Blinking blue
Software upgrade in progress
Cycling through green, red, and
off
Discovery/join process in progress
Rapidly cycling through blue,
green, and red
Access point location command invoked
Blinking red
Ethernet link not operational
Boot loader warnings
Blinking blue
Configuration recovery in progress (MODE button pushed
for 2…3 seconds)
Red
Ethernet failure or image recovery.
(MODE button pushed for 20…30 seconds)
Blinking green
Image recovery in progress (MODE button released)
Boot loader errors
Red
DRAM memory test failure
Blinking red and blue
Nonvolatile memory file system failure
Blinking red and off
Environment variable failure
Bad MAC address
Ethernet failure during image recovery
Start environment failure
No Cisco image file
Start failure
Cisco IOS errors
Red
Software failure; try disconnecting and reconnecting unit
power
Cycling through blue, green,
red, and off
General warning; insufficient in-line power
TIP
The power injector requires approximately 50 seconds to recover from
an overcurrent or overvoltage condition.
Table 4 - Status Indicator Descriptions (Continued)
Message Type
Status Indicator
Description
Содержание 1783-WAPAK9
Страница 240: ...240 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 6 Administering the WAP Access Notes...
Страница 300: ...300 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 8 Configuring Multiple SSIDs Notes...
Страница 440: ...440 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 14 Configuring RADIUS and TACACS Servers Notes...
Страница 456: ...456 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 15 Configuring VLANs...
Страница 476: ...476 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 16 Configuring QoS Notes...
Страница 482: ...482 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 17 Configuring Filters...
Страница 489: ...Rockwell Automation Publication 1783 UM006A EN P May 2014 489 Configuring Filters Chapter 17...
Страница 520: ...520 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 19 Configuring SNMP Notes...
Страница 572: ...572 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 21 Troubleshooting Notes...
Страница 578: ...578 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix A Protocol Filters Notes...
Страница 594: ...594 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix C Error and Event Messages Notes...
Страница 600: ...600 Rockwell Automation Publication 1783 UM006A EN P May 2014 Glossary Notes...
Страница 610: ...610 Rockwell Automation Publication 1783 UM006A EN P May 2014 Index Notes...
Страница 611: ......