![Allen-Bradley 1783-WAPAK9 Скачать руководство пользователя страница 233](http://html1.mh-extra.com/html/allen-bradley/1783-wapak9/1783-wapak9_user-manual_2900827233.webp)
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
233
Administering the WAP Access
Chapter 6
3.
Return to privileged EXEC mode.
end
4.
Verify your entries.
show running-config
5.
(Optional) Save your entries in the configuration file.
copy running-config startup-config
The
minutes-offset
variable in the
clock timezone
global
configuration command is available for those cases where a local time zone is a
percentage of an hour different from UTC. For example, the time zone for some
sections of Atlantic Canada (AST) is UTC-3.5, where the 3 means 3 hours .5
means 50 percent. In this case, the necessary command is:
clock timezone AST -3 30.
To set the time to UTC, use the
no clock timezone
global configuration
command.
Configuring Summer Time (Daylight Saving Time)
Beginning in privileged EXEC mode, follow these steps to configure summer
time (daylight saving time) in areas where it starts and ends on a particular day of
the week each year:
1.
Enter global configuration mode.
configure terminal
2.
Configure summer time to start and end on the specified days every year.
Summer time is disabled by default. If you specify
clock summer-time
zone recurring
without parameters, the summer time rules default to
the United States rules.
•
For
zone
, specify the name of the time zone (for example, PDT) to be
displayed when summer time is in effect.
•
(Optional) For
week
, specify the week of the month (1…5 or last).
•
(Optional) For
day
, specify the day of the week (Sunday, Monday...).
•
(Optional) For
month
, specify the month ( January, February...).
•
(Optional) For
hh:mm
, specify the time (24-hour format) in hours and
minutes.
•
(Optional) For
offset
, specify the number of minutes to add during
summer time. The default is 60.
clock summer-time zone recurring [week day month
hh:mm week day month hh:mm [offset]]
3.
Return to privileged EXEC mode.
end
Содержание 1783-WAPAK9
Страница 240: ...240 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 6 Administering the WAP Access Notes...
Страница 300: ...300 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 8 Configuring Multiple SSIDs Notes...
Страница 440: ...440 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 14 Configuring RADIUS and TACACS Servers Notes...
Страница 456: ...456 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 15 Configuring VLANs...
Страница 476: ...476 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 16 Configuring QoS Notes...
Страница 482: ...482 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 17 Configuring Filters...
Страница 489: ...Rockwell Automation Publication 1783 UM006A EN P May 2014 489 Configuring Filters Chapter 17...
Страница 520: ...520 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 19 Configuring SNMP Notes...
Страница 572: ...572 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 21 Troubleshooting Notes...
Страница 578: ...578 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix A Protocol Filters Notes...
Страница 594: ...594 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix C Error and Event Messages Notes...
Страница 600: ...600 Rockwell Automation Publication 1783 UM006A EN P May 2014 Glossary Notes...
Страница 610: ...610 Rockwell Automation Publication 1783 UM006A EN P May 2014 Index Notes...
Страница 611: ......